Cảm biến áp suất IFM PN2296 -0.125…2.5 bar

Product characteristics
Output signal switching signal; analogue signal; IO-Link; (configurable)
Measuring range
 
-0.125…2.5 bar -125…2500 mbar -1.8…36.25 psi -12.5…250 kPa
Process connection threaded connection 1/4″ NPT internal thread
Application
Special feature Gold-plated contacts
Measuring element ceramic-capacitive pressure measuring cell
Application for industrial applications
Media liquids and gases
Medium temperature [°C] -25…80
Min. bursting pressure
 
50 bar 725 psi 5000 kPa
Pressure rating
 
20 bar 290 psi 2000 kPa
Vacuum resistance [mbar] -1000
Type of pressure relative pressure
MAWP (for applications according to CRN)
 
20 bar 290 psi 2000 kPa
Electrical data
Operating voltage [V] 18…30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA] < 35
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250
Switching frequency DC [Hz] < 500
Number of analogue outputs 1
Analogue current output [mA] 4…20; (scalable 1:5)
Max. load [Ω] 500
Analogue voltage output [V] 0…10; (scalable 1:5)
Min. load resistance [Ω] 2000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
 
-0.125…2.5 bar -125…2500 mbar -1.8…36.25 psi -12.5…250 kPa
Analogue start point
 
-0.125…2 bar -1.8…29 psi -12.5…200 kPa
Analogue end point
 
0.375…2.5 bar 5.45…36.25 psi 37.5…250 kPa
Factory setting / CMPT = 2
Set point SP
 
-0.11…2.5 bar -1.6…36.25 psi -11…250 kPa
Reset point rP
 
-0.12…2.49 bar -1.75…36.1 psi -12…249 kPa
Min. difference between SP and rP
 
0.015 bar 0.15 psi 1.5 kPa
In steps of
 
0.005 bar 0.05 psi 0.5 kPa
Status_B High Resolution / CMPT = 3
Set point SP
 
-0.109…2.5 bar -1.58…36.26 psi -10.9…250 kPa
Reset point rP
 
-0.12…2.49 bar -1.73…36.11 psi -12…249 kPa
Min. difference between SP and rP
 
0.011 bar 0.15 psi 1.1 kPa
In steps of
 
0.001 bar 0.01 psi 0.1 kPa
Accuracy / deviations
Notes on the accuracy / deviation switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
Switch point accuracy [% of the span] < ± 0,4; (Turn down 1:1)
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span] < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span] < ± 0,1; (Turn down 1:1)
Long-term stability [% of the span] < ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point [% of the span / 10 K] < ± 0,2; (-0…80 °C)
Temperature coefficient span [% of the span / 10 K] < ± 0,2; (-0…80 °C)
Response times
Response time [ms] < 1.5
Delay time programmable dS, dr [s] 0…50
Damping for the switching output dAP [s] 0…4
Damping for the analogue output dAA [s] 0…4
Max. response time analogue output [ms] 3
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
SIO mode yes
Required master port type A; (wenn PIN 2 nicht verbunden: B)
Supported DeviceIDs
 
Type of operation DeviceID
Factory setting / CMPT = 2 474
Status_B High Resolution / CMPT = 3 990
Note

Sản phẩm cùng loại

Gửi tin nhắn
Gọi cho chúng tôi
Chat qua facebook
Chat qua zalo
Văn phòng