Cảm biến áp suất IFM PN7571 0…250 bar

Product characteristics
Output signal switching signal; IO-Link; (configurable)
Measuring range
 
0…250 bar 0…3620 psi 0…25 MPa
Process connection threaded connection G 1/4 external thread internal thread:M5
Application
Special feature Gold-plated contacts
Measuring element metallic thin film cell
Application for industrial applications
Media liquids and gases
Medium temperature [°C] -25…80
Min. bursting pressure
 
1100 bar 15950 psi 110 MPa
Pressure rating
 
500 bar 7250 psi 50 Mpa
Vacuum resistance [mbar] -1000
Type of pressure relative pressure
Electrical data
Operating voltage [V] 18…30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA] < 35
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2
Outputs
Total number of outputs 2
Output signal switching signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 150; (200 (…60 °C) 250 (…40 °C))
Switching frequency DC [Hz] < 170
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
 
0…250 bar 0…3620 psi 0…25 MPa
Factory setting / CMPT = 2
Set point SP
 
2…250 bar 40…3620 psi 0.2…25 MPa
Reset point rP
 
1…249 bar 20…3600 psi 0.1…24.9 MPa
Min. difference between SP and rP
 
2 bar 20 psi 0.2 MPa
In steps of
 
1 bar 20 psi 0.1 MPa
Status_B High Resolution / CMPT = 3
Set point SP
 
2…250 bar 30…3626 psi 0.2…25 MPa
Reset point rP
 
1…249 bar 12…3608 psi 0.1…24.9 MPa
Min. difference between SP and rP
 
2 bar 19 psi 0.2 MPa
In steps of
 
1 bar 1 psi 0.1 MPa
Accuracy / deviations
Switch point accuracy [% of the span] < ± 0,5
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span] < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span] < ± 0,25
Long-term stability [% of the span] < ± 0,05; (per 6 months)
Temperature coefficient zero point [% of the span / 10 K] 0,2; (-25…80 °C)
Temperature coefficient span [% of the span / 10 K] 0,2; (-25…80 °C)
Response times
Response time [ms] < 3
Delay time programmable dS, dr [s] 0…50
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
SIO mode yes
Required master port type A; (when pin 2 not connected: B)
Process data analogue 1
Process data binary 2
Supported DeviceIDs
 
Type of operation DeviceID
Factory setting / CMPT = 2 400
Status_B High Resolution / CMPT = 3 598
PN7001 308
Note
 
For further information please see the IODD PDF file under “Downloads”
Factory setting / CMPT = 2
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
Min. process cycle time [ms] 2.3
IO-Link resolution pressure [bar] 1
IO-Link resolution pressure [MPa] 0.1
IO-Link process data (cyclical)
 
function bit length
pressure 14
binary switching information 2
IO-Link functions (acyclical) application specific tag
Status_B High Resolution / CMPT = 3
Profiles Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
Min. process cycle time [ms] 3
IO-Link resolution pressure [bar] 0.1
IO-Link resolution pressure [MPa] 0.02