Cảm biến áp suất IFM PN7593 0…25 bar

Sản phẩm cùng loại

Gửi tin nhắn
Gọi cho chúng tôi
Chat qua facebook
Chat qua zalo
Văn phòng
Product characteristics
Output signal switching signal; IO-Link; (configurable)
Measuring range
 
0…25 bar 0…362 psi 0…2.5 MPa
Process connection threaded connection G 1/4 external thread internal thread:M5
Application
Special feature Gold-plated contacts
Measuring element ceramic-capacitive pressure measuring cell
Application for industrial applications
Media liquids and gases
Conditionally suitable for For gaseous media the application is limited to max. 25 bar.
Medium temperature [°C] -25…80
Min. bursting pressure
 
350 bar 5075 psi 35 MPa
Pressure rating
 
150 bar 2175 psi 15 Mpa
Vacuum resistance [mbar] -1000
Type of pressure relative pressure
Electrical data
Operating voltage [V] 18…30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA] < 35
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] < 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2
Outputs
Total number of outputs 2
Output signal switching signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 150; (200 (…60 °C) 250 (…40 °C))
Switching frequency DC [Hz] < 170
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
 
0…25 bar 0…362 psi 0…2.5 MPa
Factory setting / CMPT = 2
Set point SP
 
0.2…25 bar 4…362 psi 0.02…2.5 MPa
Reset point rP
 
0.1…24.9 bar 2…360 psi 0.01…2.49 MPa
Min. difference between SP and rP
 
0.2 bar 2 psi 0.02 MPa
In steps of
 
0.1 bar 2 psi 0.01 MPa
Status_B High Resolution / CMPT = 3
Set point SP
 
0.2…25 bar 3…363 psi 0.02…2.5 MPa
Reset point rP
 
0.1…24.9 bar 1…361 psi 0.01…2.49 MPa
Min. difference between SP and rP
 
0.2 bar 2 psi 0.02 MPa
In steps of
 
0.1 bar 1 psi 0.01 MPa
Accuracy / deviations
Switch point accuracy [% of the span] < ± 0,5
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span] < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span] < ± 0,25
Long-term stability [% of the span] < ± 0,05; (per 6 months)
Temperature coefficient zero point [% of the span / 10 K] < ± 0,2; (-0…80 °C)
Temperature coefficient span [% of the span / 10 K] < ± 0,2; (-0…80 °C)
Response times
Response time [ms] < 3
Delay time programmable dS, dr [s] 0…50
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
SIO mode yes
Required master port type A; (when pin 2 not connected: B)
Process data analogue 1
Process data binary 2
Supported DeviceIDs
 
Type of operation DeviceID
Factory setting / CMPT = 2 402
Status_B High Resolution / CMPT = 3 600
PN7003 310
Note
 
For further information please see the IODD PDF file under “Downloads”
Factory setting / CMPT = 2
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
Min. process cycle time [ms] 2.3
IO-Link resolution pressure [bar] 0.1
IO-Link resolution pressure [MPa] 0.01
IO-Link process data (cyclical)
 
function bit length
pressure 14
binary switching information 2
IO-Link functions (acyclical) application specific tag
Status_B High Resolution / CMPT = 3
Profiles Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
Min. process cycle time [ms] 3
IO-Link resolution pressure [bar] 0.01
IO-Link resolution pressure [MPa] 0.001