Product characteristics |
Output signal |
switching signal; analogue signal; IO-Link; (configurable) |
Measuring range |
-1…1 bar |
-1000…1000 mbar |
-14.6…14.6 psi |
-29.4…29.4 inHg |
-100…100 kPa |
|
Process connection |
threaded connection G 1/8 internal thread internal thread:M5 |
Application |
Special feature |
Gold-plated contacts |
Application |
for industrial applications |
Conditionally suitable for |
other media on request |
Medium temperature [°C] |
0…60 |
Min. bursting pressure |
30 bar |
435 psi |
886 inHg |
3000 kPa |
|
Note on min. burst pressure |
max. overpressure on second pressure connection: 12 bar / 1200 kPa / 174 PSI / 354,4 inHg / 1,2 MPa |
|
Pressure rating |
20 bar |
290 psi |
591 inHg |
2000 kPa |
|
Vacuum resistance [mbar] |
-1000 |
Type of pressure |
relative pressure; differential pressure; vacuum |
Electrical data |
Operating voltage [V] |
18…32 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] |
< 50 |
Min. insulation resistance [MΩ] |
100; (500 V DC) |
Protection class |
III |
Reverse polarity protection |
yes |
Overvoltage protection |
yes; (< 40 V) |
Power-on delay time [s] |
0.5 |
Integrated watchdog |
yes |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; analogue signal; IO-Link; (configurable) |
Electrical design |
PNP |
Number of digital outputs |
1 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2 |
Permanent current rating of switching output DC [mA] |
100 |
Switching frequency DC [Hz] |
< 100 |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4…20 |
Max. load [Ω] |
500 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Measuring/setting range |
Measuring range |
-1…1 bar |
-1000…1000 mbar |
-14.6…14.6 psi |
-29.4…29.4 inHg |
-100…100 kPa |
|
Set point SP |
-0.98…1 bar |
-14.2…14.6 psi |
-28.8…29.4 inHg |
-98…100 kPa |
|
Reset point rP |
-0.99…0.99 bar |
-14.4…14.4 psi |
-29.1…29.1 inHg |
-99…99 kPa |
|
In steps of |
0.01 bar |
0.2 psi |
0.3 inHg |
1 kPa |
|
Accuracy / deviations |
Switch point accuracy [% of the span] |
< ± 0,5 |
Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span] |
< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span] |
< ± 0,25 |
Long-term stability [% of the span] |
< ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K] |
0,2; (0…60 °C) |
Temperature coefficient span [% of the span / 10 K] |
0,2; (0…60 °C) |
Response times |
Response time [ms] |
< 6 |
Delay time programmable dS, dr [s] |
0; 0,002…5 |
Step response time analogue output [ms] |
6 |
Software / programming |
Parameter setting options |
hysteresis / window; normally open / normally closed; analogue output; IO-Link; switching logic; switch-on/switch-off delay; Damping; Display unit |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 FDIS |
Profiles |
Smart Sensor: Process Data Variable; Device Identification |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
1 |
Process data binary |
2 |
Min. process cycle time [ms] |
2.3 |
Supported DeviceIDs |
Type of operation |
DeviceID |
Default |
366 |
|
Operating conditions |
Ambient temperature [°C] |
0…70 |
Storage temperature [°C] |
-25…85 |
Protection |
IP 65 |
Mechanical data |
Weight [g] |
86.5 |
Materials |
PBT; FKM; polyester |
Materials (wetted parts) |
brass; FKM; silicon (coated); PBT |
Min. pressure cycles |
50 million |
Process connection |
threaded connection G 1/8 internal thread internal thread:M5 |
Displays / operating elements |
Display |
Display unit |
4 x LED, green |
switching status |
1 x LED, yellow |
function display |
alphanumeric display, 4-digit |
measured values |
alphanumeric display, 4-digit |
|
Display unit |
bar; kPa; psi; inHg |
Remarks |
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M8; Contacts: gold-plated |