Cảm biến lưu lượng IFM SD5600 16 bar

Sản phẩm cùng loại

Gửi tin nhắn
Gọi cho chúng tôi
Chat qua facebook
Chat qua zalo
Văn phòng
Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
 
0.8…250 l/min 0.3…82.9 m/s 0.05…15 m³/h
Process connection threaded connection G 1/4 DN8
Application
Application for industrial applications
Media Argon (Ar); carbon dioxide (CO2); nitrogen (N2); compressed air
Medium temperature [°C] -10…60
Min. bursting pressure [bar] 64
Min. bursting pressure [MPa] 6.4
Pressure rating [bar] 16
Pressure rating [Mpa] 1.6
Electrical data
Operating voltage [V] 18…30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA] < 80
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 1
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputs counter reset
Outputs
Output signal switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 150; (per output)
Number of analogue outputs 1
Analogue current output [mA] 4…20; (scalable)
Max. load [Ω] 500
Pulse output consumed quantity meter
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
 
0.8…250 l/min 0.3…82.9 m/s 0.05…15 m³/h
Display range
 
0…300 l/min 0…99.5 m/s 0…18 m³/h
Resolution
 
0.2 l/min 0.1 m/s 0.01 m³/h
Set point SP
 
2.2…249.9 l/min 0.7…82.9 m/s 0.13…14.99 m³/h
Reset point rP
 
0.9…248.7 l/min 0.3…82.5 m/s 0.06…14.92 m³/h
Analogue start point ASP
 
0…200 l/min 0…66.3 m/s 0…12 m³/h
Analogue end point AEP
 
50…250 l/min 16.6…82.9 m/s 3…15 m³/h
Low flow cut-off LFC
 
0.3…2.7 l/min 0.1…0.9 m/s 0.02…0.16 m³/h
In steps of
 
0.1 l/min 0.1 m/s 0.01 m³/h
Pressure monitoring
Measuring range [bar] -1…16
Display range [bar] -1…20
Resolution [bar] 0.05
Set point SP [bar] -0.92…16
Reset point rP [bar] -1…15.92
Analogue start point [bar] -1…12.8
Analogue end point [bar] 2.2…16
In steps of [bar] 0.01
Volumetric flow quantity monitoring
Measuring range
 
0…100000000 m³ 0…353146667.2 scf
Display range
 
0…100000000 m³ 0…353146667.2 scf
Set point SP
 
0.001…10000000 m³ 0.05…353146667.2 scf
Pulse value
 
0.001…10000000 m³ 0.05…353146667.2 scf
In steps of
 
0.0001 m³ 0.005 scf
Pulse length [s] 0.01…2
Temperature monitoring
Measuring range
 
-10…60 °C 14…140 °F
Display range
 
-24…74 °C -11.2…165.2 °F
Resolution
 
0.2 °C 0.5 °F
Set point SP
 
-9.7…60 °C 14.6…140 °F
Reset point rP
 
-10…59.7 °C 14…139.4 °F
Analogue start point
 
-10…46 °C 14…114.8 °F
Analogue end point
 
4…60 °C 39.2…140 °F
In steps of
 
0.1 °C 0.1 °F
Accuracy / deviations
Temperature coefficient [1/K] ± 0,07 % MW
Accuracy (in the measuring range) ± (6 % MW + 0,6 % MEW); at medium temperature 23 °C