| Product characteristics |
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
| Measuring range |
| 0.8…83.4 l/min |
0.3…27.6 m/s |
0.05…5 m³/h |
|
| Process connection |
threaded connection G 1/4 DN8 |
| Application |
| Application |
for industrial applications |
| Media |
helium |
| Medium temperature [°C] |
-10…60 |
| Min. bursting pressure [bar] |
64 |
| Pressure rating [bar] |
16 |
| Electrical data |
| Operating voltage [V] |
18…30 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA] |
< 80 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time [s] |
1 |
| Inputs / outputs |
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
| Inputs |
| Inputs |
counter reset |
| Outputs |
| Output signal |
switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] |
2.5 |
| Permanent current rating of switching output DC [mA] |
150; (per output) |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4…20; (scalable) |
| Max. load [Ω] |
500 |
| Pulse output |
consumed quantity meter |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Overload protection |
yes |
| Measuring/setting range |
| Measuring range |
| 0.8…83.4 l/min |
0.3…27.6 m/s |
0.05…5 m³/h |
|
| Display range |
| 0…100 l/min |
0…33.1 m/s |
0…6 m³/h |
|
| Resolution |
| 0.2 l/min |
0.1 m/s |
0.01 m³/h |
|
| Set point SP |
| 1.3…83.3 l/min |
0.4…27.6 m/s |
0.08…5 m³/h |
|
| Reset point rP |
| 0.9…82.9 l/min |
0.3…27.5 m/s |
0.05…4.97 m³/h |
|
| Analogue start point ASP |
| 0…66.6 l/min |
0…22.1 m/s |
0…4 m³/h |
|
| Analogue end point AEP |
| 16.7…83.3 l/min |
5.5…27.6 m/s |
1…5 m³/h |
|
| Low flow cut-off LFC |
| 0.6…0.8 l/min |
0.2…0.3 m/s |
0.04…0.05 m³/h |
|
| In steps of |
| 0.1 l/min |
0.1 m/s |
0.01 m³/h |
|
| Pressure monitoring |
| Measuring range [bar] |
-1…16 |
| Display range [bar] |
-1…20 |
| Resolution [bar] |
0.05 |
| Set point SP [bar] |
-0.92…16 |
| Reset point rP [bar] |
-1…15.92 |
| Analogue start point [bar] |
-1…12.8 |
| Analogue end point [bar] |
2.2…16 |
| In steps of [bar] |
0.01 |
| Volumetric flow quantity monitoring |
| Measuring range |
| 0…100000000 m³ |
0…353146667.2 scf |
|
| Display range |
| 0…100000000 m³ |
0…353146667.2 scf |
|
| Set point SP |
| 0.001…10000000 m³ |
0.05…353146667.2 scf |
|
| Pulse value |
| 0.001…10000000 m³ |
0.05…353146667.2 scf |
|
| In steps of |
|
| Pulse length [s] |
0.01…2 |
| Temperature monitoring |
| Measuring range |
|
| Display range |
|
| Resolution |
|
| Set point SP |
|
| Reset point rP |
|
| Analogue start point |
|
| Analogue end point |
|
| In steps of |
|
| Accuracy / deviations |
| Temperature coefficient [1/K] |
± 0,07 % MW |
| Accuracy (in the measuring range) |
± (6 % MW + 0,6 % MEW); at medium temperature 23 °C |
| Repeatability |
0,8 % MW + 0,2 % MEW |
| Pressure monitoring |
| Repeatability [% of the final value] |
Sản phẩm cùng loại
Chat qua zalo
Để lại thông tin - Nhận giá ưu đãi
Gọi cho CÔNG NGHIỆP VÀ TỰ ĐỘNG HÓA COZIC để nhận tư vấn tốt nhất
Địa chỉ - CÔNG NGHIỆP VÀ TỰ ĐỘNG HÓA COZIC
78 Hoà Minh 1 - Hoà Minh - Liên Chiểu - Đà Nẵng - Việt Nam
Văn phòng - CÔNG NGHIỆP VÀ TỰ ĐỘNG HÓA COZIC
VP: 16 Vũ Huy Tấn - Hoà Hiệp Nam - Liên Chiểu- Đà Nẵng- Việt Nam
Thông báo sẽ tự động tắt sau 5 giây ...
|