Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Process connection |
threaded connection 1/2″ NPT DN15 |
Ar |
Measuring range |
15…4310 scfh |
0.2…71.8 scfm |
2…552 sfs |
|
CO2 |
Measuring range |
10…2640 scfh |
0.15…44 scfm |
1…338.5 sfs |
|
N2 |
Measuring range |
10…2650 scfh |
0.15…44.15 scfm |
1…339.5 sfs |
|
Application |
Application |
for industrial applications |
Media |
Argon (Ar); carbon dioxide (CO2); nitrogen (N2) |
Medium temperature [°F] |
32…140 |
Pressure rating [bar] |
16 |
Pressure rating [psi] |
232 |
MAWP (for applications according to CRN) [bar] |
16 |
Electrical data |
Operating voltage [V] |
18…30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] |
< 100 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
1 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
Electrical design |
PNP |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2 |
Permanent current rating of switching output DC [mA] |
250; (per output) |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4…20; (scalable) |
Max. load [Ω] |
500 |
Pulse output |
consumed quantity meter |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring/setting range |
Low flow cut-off LFC |
< 46 scfh |
< 0.76 scfm |
1…5.8 sfs |
|
Measuring dynamics |
1:300 |
Ar |
Measuring range |
15…4310 scfh |
0.2…71.8 scfm |
2…552 sfs |
|
Display range |
0…5170 scfh |
0…86.2 scfm |
0…663 sfs |
|
Resolution |
|
Set point SP |
40…4310 scfh |
0.7…71.8 scfm |
5…552 sfs |
|
Reset point rP |
20…4290 scfh |
0.4…71.5 scfm |
3…550 sfs |
|
Analogue start point ASP |
0…3445 scfh |
0…57.4 scfm |
0…442 sfs |
|
Analogue end point AEP |
860…4310 scfh |
14.4…71.8 scfm |
110…552 sfs |
|
In steps of |
|
CO2 |
Measuring range |
10…2640 scfh |
0.15…44 scfm |
1…338.5 sfs |
|
Display range |
0…3170 scfh |
0…52.8 scfm |
0…406 sfs |
|
Resolution |
|
Set point SP |
25…2640 scfh |
0.4…44 scfm |
3…338.5 sfs |
|
Reset point rP |
15…2630 scfh |
0.2…43.8 scfm |
1.5…337 sfs |
|
Analogue start point ASP |
0…2110 scfh |
0…35.2 scfm |
0…271 sfs |
|
Analogue end point AEP |
530…2640 scfh |
8.8…44 scfm |
67.5…338.5 sfs |
|
In steps of |
|
Volumetric flow quantity monitoring |
Pulse value |
0.040…4 000 000 scf |
In steps of |
0.020…1000 scf |
Pulse length [s] |
0,007…2 |
N2 |
Measuring range |
10…2650 scfh |
0.15…44.15 scfm |
1…339.5 sfs |
|
Display range |
0…3175 scfh |
0…52.95 scfm |
0…407.5 sfs |
|
Resolution |
Sản phẩm cùng loại
Chat qua zalo
Để lại thông tin - Nhận giá ưu đãi
Gọi cho CÔNG NGHIỆP VÀ TỰ ĐỘNG HÓA COZIC để nhận tư vấn tốt nhất
Địa chỉ - CÔNG NGHIỆP VÀ TỰ ĐỘNG HÓA COZIC
78 Hoà Minh 1 - Hoà Minh - Liên Chiểu - Đà Nẵng - Việt Nam
Văn phòng - CÔNG NGHIỆP VÀ TỰ ĐỘNG HÓA COZIC
VP: 16 Vũ Huy Tấn - Hoà Hiệp Nam - Liên Chiểu- Đà Nẵng- Việt Nam
Thông báo sẽ tự động tắt sau 5 giây ...
| |