| Product characteristics |
| Number of inputs and outputs |
Number of digital outputs: 2 |
| Process connection |
M18 x 1,5 internal thread |
| Application |
| Media |
Liquids; Gases |
| Medium temperature [°C] |
-25…80 |
| Pressure rating [bar] |
300 |
| Liquids |
| Medium temperature [°C] |
-25…80 |
| Gases |
| Medium temperature [°C] |
-25…80 |
| Electrical data |
| Operating voltage [V] |
18…36 DC |
| Current consumption [mA] |
< 60 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time [s] |
10 |
| Inputs / outputs |
| Number of inputs and outputs |
Number of digital outputs: 2 |
| Outputs |
| Total number of outputs |
2 |
| Output signal |
switching signal; IO-Link; (configurable) |
| Electrical design |
PNP |
| Number of digital outputs |
2 |
| Output function |
normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] |
2.5 |
| Permanent current rating of switching output DC [mA] |
250 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Overload protection |
yes |
| Measuring/setting range |
| Probe length L [mm] |
45 |
| Liquids |
| Setting range [cm/s] |
3…300 |
| Greatest sensitivity [cm/s] |
3…100 |
| Gases |
| Setting range [cm/s] |
200…3000 |
| Greatest sensitivity [cm/s] |
200…800 |
| Temperature monitoring |
| Measuring range [°C] |
2…80 |
| Resolution [°C] |
1 |
| Accuracy / deviations |
| Repeatability [cm/s] |
1…5 |
| Note on repeatability |
| for water 5…100 cm/s; 25 °C |
| Factory setting |
|
| Temperature drift [cm/s x 1/K] |
0.1; (for water 5…100 cm/s; 10…70 °C) |
| Temperature gradient [K/min] |
300 |
| Switch point accuracy [cm/s] |
± 2…± 10; (for water 5…100 cm/s; 25 °C; Factory setting) |
| Hysteresis [cm/s] |
2…5; (for water 5…100 cm/s; 25 °C; Factory setting) |
| Temperature monitoring |
| Switch point accuracy [K] |
± 3 (v > 5cm/s); (Liquids) |
| Resolution [K] |
1 |
| Repeatability [K] |
2 |
| Response times |
| Response time [s] |
1…10 |
| Liquids |
| Response time [s] |
1…10 |
| Gases |
| Response time [s] |
1…10 |
| Temperature monitoring |
| Response time [s] |
1…10 |
| Software / programming |
| Adjustment of the switch point |
pushbutton |
| Interfaces |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
Smart Sensor: Process Data Variable; Device Identification |
| SIO mode |
yes |
| Required master port type |
A |
| Process data analogue |
2 |
| Process data binary |
2 |
| Min. process cycle time [ms] |
3 |
| Supported DeviceIDs |
| Type of operation |
DeviceID |
| Default |
53 |
|
| Operating conditions |
| Ambient temperature [°C] |
-25…80 |
| Storage temperature [°C] |
-25…100 |
| Protection |
IP 65; IP 67 |
| Mechanical data |
| Weight [g] |
254 |
| Dimensions [mm] |
M18 x 1.5 |
| Thread designation |
M18 x 1.5 |
| Materials |
stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PC; PBT-GF20; EPDM/X |
| Materials (wetted parts) |
stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A |
| Process connection |
M18 x 1,5 internal thread |
| Displays / operating elements |
| Display |
| function |
10 x LED, three-colour |
|
| Remarks |
| Pack quantity |
1 pcs. |
| Electrical connection |
| Connection |
Connector: 1 x M12 |