| Product characteristics | |||||
|---|---|---|---|---|---|
| Number of inputs and outputs | Number of analogue outputs: 1 | ||||
| Measuring range [l/min] | 0.1…25 | ||||
| Process connection | threaded connection G 1/2 DN15 flat seal | ||||
| Application | |||||
| Special feature | Gold-plated contacts | ||||
| Application | for industrial applications | ||||
| Installation | connection to pipe by means of an adapter | ||||
| Media | conductive liquids; water; hydrous media | ||||
| Note on media |
|
||||
| Medium temperature [°C] | -10…70 | ||||
| Pressure rating [bar] | 16 | ||||
| Pressure rating [Mpa] | 1.6 | ||||
| MAWP (for applications according to CRN) [bar] | 17.7 | ||||
| Electrical data | |||||
| Operating voltage [V] | 18…30 DC; (according to EN 50178 SELV/PELV) | ||||
| Current consumption [mA] | 95; (24 V) | ||||
| Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||
| Protection class | III | ||||
| Reverse polarity protection | yes | ||||
| Power-on delay time [s] | 5 | ||||
| Inputs / outputs | |||||
| Number of inputs and outputs | Number of analogue outputs: 1 | ||||
| Outputs | |||||
| Total number of outputs | 1 | ||||
| Output signal | analogue signal; IO-Link; (configurable) | ||||
| Permanent current rating of switching output DC [mA] | 250 | ||||
| Number of analogue outputs | 1 | ||||
| Analogue current output [mA] | 4…20 | ||||
| Max. load [Ω] | 500 | ||||
| Overload protection | yes | ||||
| Measuring/setting range | |||||
| Measuring range [l/min] | 0.1…25 | ||||
| Accuracy / deviations | |||||
| Flow monitoring | |||||
| Accuracy (in the measuring range) | ± (0,8 % MW + 0,5 % MEW) | ||||
| Repeatability | ± 0,2% MEW | ||||
| Response times | |||||
| Flow monitoring | |||||
| Response time [s] | 0.15; (dAP = 0, T19) | ||||
| Temperature monitoring | |||||
| Dynamic response T05 / T09 [s] | T09 = 20 (Q > 1 l/min) | ||||
| Interfaces | |||||
| Communication interface | IO-Link | ||||
| Transmission type | COM2 (38,4 kBaud) | ||||
| IO-Link revision | 1.1 | ||||
| SDCI standard | IEC 61131-9 | ||||
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | ||||
| SIO mode | yes | ||||
| Required master port type | A | ||||
| Process data analogue | 2 | ||||
| Min. process cycle time [ms] | 3 | ||||
| Supported DeviceIDs |
|
||||
| Operating conditions | |||||
| Ambient temperature [°C] | -10…60 | ||||
| Storage temperature [°C] | -25…80 | ||||
| Protection | IP 67 | ||||
| Mechanical data | |||||
| Weight [g] | 491 | ||||
| Materials | stainless steel (1.4404 / 316L); PBT-GF20; FKM; TPE | ||||
| Materials (wetted parts) | stainless steel (1.4404 / 316L); PEEK; FKM | ||||
| Process connection | threaded connection G 1/2 DN15 flat seal | ||||
| Remarks | |||||
| Remarks |
|
||||
| Pack quantity | 1 pcs. | ||||
| Electrical connection | |||||
| Connection | Connector: 1 x M12; Contacts: gold-plated | ||||