Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 2 |
Measuring range |
|
Process connection |
threaded connection G 1 flat seal |
Application |
Special feature |
Gold-plated contacts |
Application |
for industrial applications |
Installation |
connection to pipe by means of an adapter |
Media |
water; glycol solutions; coolants; oil |
Note on media |
low-viscosity oils with viscosity: 7…40 mm²/s (40 °C) |
high-viscosity oils with viscosity: 30…68 mm²/s (40 °C) |
|
Medium temperature [°C] |
-10…80 |
Pressure rating [bar] |
16 |
Pressure rating [Mpa] |
1.6 |
Electrical data |
Operating voltage [V] |
19…30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] |
100 |
Min. insulation resistance [MΩ] |
100; (500 V DC) |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
10 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2 |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal |
Electrical design |
PNP |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2 |
Permanent current rating of switching output DC [mA] |
250; (per output) |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring/setting range |
Measuring range |
|
Display range |
|
Resolution |
|
Set point SP |
0.2…100 l/min |
0.06…26.42 gpm |
|
Reset point rP |
|
Max. flow rate [l/min] |
110 |
In steps of |
|
Temperature monitoring |
Measuring range [°C] |
-10…80 |
Resolution [°C] |
0.2 |
Set point SP [°C] |
-9.8…80 |
Reset point rP [°C] |
-10…79.8 |
In steps of [°C] |
0.2 |
Accuracy / deviations |
Flow monitoring |
Accuracy (in the measuring range) |
< ± (3 % MW + 0,2 % MEW) / < ± (5 % MW + 0,5 % MEW); (water; glycol: 35%; oil: viscosity 68 mm²/s at 40 °C) |
Repeatability |
0,2 l/min (0,05 gpm) |
Temperature monitoring |
Accuracy [K] |
0,2 |
Response times |
Flow monitoring |
Response time [s] |
0.25; (dAP = 0) |
Delay time programmable dS, dr [s] |
0…50 |
Damping for the switching output dAP [s] |
0…1 |
Temperature monitoring |
Dynamic response T05 / T09 [s] |
T09 = 70 (Q > 5 l/min); (water) |
Software / programming |
Parameter setting options |
Flow monitoring; Temperature monitoring |
Operating conditions |
Ambient temperature [°C] |
-10…60 |
Storage temperature [°C] |
-25…80 |
Protection |
IP 67 |
Mechanical data |
Weight [g] |
1694 |
Materials |
housing: AlMgSi0,5 anodised; Sealing: FKM; connector housing: brass Optalloy-plated; PA 6.6; cover film: PA |
Materials (wetted parts) |
stainless steel (1.4404 / 316L); FKM; PES; Centellen 200 |
Process connection |
threaded connection G 1 flat seal |
Displays / operating elements |
Display |
Display unit |
4 x LED, green (l/min, m³/h, gal/min, gal/h) |
Display unit |
2 x LED, yellow (°C / °F) |
switching status |
2 x LED, yellow |
measured values |
alphanumeric display, 4-digit |
programming |
alphanumeric display, 4-digit |
|
Display unit |
l/min; m³/h; gpm; gph; °C; °F |
Accessories |
Accessories (supplied) |
|
Accessories (optional) |
adapter for pipe: 1 x R 1/2, stainless steel, E40179 |
adapter for pipe: 1 x R 3/4, stainless steel, E40180 |
adapter for pipe: 1 x 1/2″ NPT, stainless steel, E40192 |
adapter for pipe: 1 x 3/4″ NPT, stainless steel, E40193 |
adapter for pipe: 1 x R 1/2, brass, E40152 |
adapter for pipe: 1 x R 3/4, brass, E40153 |
adapter for pipe: 1 x 1/2″ NPT, brass, E40155 |
adapter for pipe: 1 x 3/4″ NPT, brass, E40156 |
|
Remarks |
Remarks |
MW = measured value |
MEW = Final value of the measuring range |
sealing: only with supplied Centellen seals |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12; Moulded body: brass, Optalloy-plated; Contacts: gold-plated |