Model |
FD-XS20E |
Supported pipe materials |
Metal pipes, Plastic pipes (soft/hard) *1 |
Supported fluids |
Liquids (water, oil, adhesive, grease, chemical solutions, etc.) *1 |
Supported fluid temperature |
0 °C (no freezing on the pipe surface) to 100 °C 32 to 212 °F (Pipe surface temperature) |
Clamp set model |
Plastic pipe/tube attachment |
FD-XC20R1, FD-XC20R2, FD-XC20R3, FD-XC20R4 |
Metal pipe attachment |
FD-XC20M1, FD-XC20M2*2 |
Maximum rated flow rate |
Outer diameter of pipe 3/8 ” (9.53 mm) , ø 10 0.39 “, ø 10.5 0.41 “: 15.00 L/minOuter diameter of pipe ø 12 0.47 “, 1/2 ” (12.7 mm) , ø 13.8 0.54 “: 20.00 L/min |
Zero cut flow rate |
0.15 L/min*3 (variable, default) |
Display resolution |
Instantaneous flow rate |
0.01/0.1 L/min (Displayed on controller) |
Repeatability |
Response time 50 ms: ±20 % of RDResponse time 500 ms: ±15 % of RD |
Hysteresis |
Variable |
Display method |
Status indicator |
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) , IP68G (JIS C0920) *4 |
Ambient temperature |
-10 to 60 °C 14 to 140 °F (No freezing) |
Relative humidity |
35 % to 85 %RH (No condensation) |
Vibration resistance |
10 to 55 Hz, double amplitude 1.5 mm 0.06 “, 2 hours each for X,Y,Z direction |
Shock resistance |
50 G 11 ms 3 times each for X,Y,Z direction |
Material |
Sensor head |
Head body: PPS/PPSU, relay amplifier: PPS, cable: PVC, controller connector: PPS/PBT/POM |
Clamp set |
For plastic pipe |
Body, fixing screw: PPS, detection surface: special rubber, pipe support rubber: FKM, sensor head fixing screw: SUSXM7 |
For metal pipe |
Metal: SUS304/SUSXM7, detection surface: special rubber, clamp support rubber: FKM, sensor head fixing screw: SUSXM7 |
Weight |
Approx. 260 g |