Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 2 |
Factory setting |
hydrous media |
Process connection |
threaded connection G 1/2 sealing cone |
Application |
Special feature |
Gold-plated contacts |
Media |
Liquids |
Recommended media |
water; hydrous media; oils; oil-based media |
Cannot be used for |
See the operating instructions, chapter “Function and features”. |
Probe length [mm] |
38 |
Tank pressure [bar] |
-1…40; (applications subject to the German Federal Water Act : -0,5…10 bar) |
Oil |
Medium temperature [°C] |
-25…100; (applications subject to the German Federal Water Act 0…100 °C) |
Medium temperature short time [°C] |
-25…150; (1 h; applications subject to the German Federal Water Act : 0…100 °C) |
Water |
Medium temperature [°C] |
-25…85; (applications subject to the German Federal Water Act : 0…85 °C) |
Medium temperature short time [°C] |
-25…150; (1 h; applications subject to the German Federal Water Act : 0…100 °C) |
Electrical data |
Operating voltage [V] |
18…30 DC |
Current consumption [mA] |
< 50 |
Protection class |
III |
Reverse polarity protection |
yes |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2 |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; IO-Link |
Electrical design |
PNP |
Number of digital outputs |
2 |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
100 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring/setting range |
Factory setting |
hydrous media |
Response times |
Response time [s] |
< 0.5 |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
Profiles |
Smart Sensor: Process Data Variable; Device Identification |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
1 |
Process data binary |
2 |
Min. process cycle time [ms] |
2.3 |
Supported DeviceIDs |
Type of operation |
DeviceID |
Default |
449 |
|
Operating conditions |
Ambient temperature [°C] |
-20…85 |
Note on ambient temperature |
Medium temperature 100…150 °C |
-40…60 °C |
|
Storage temperature [°C] |
-40…85 |
Protection |
IP 68; IP 69K |
Mechanical data |
Weight [g] |
249.5 |
Dimensions [mm] |
Ø 30 / L = 125 |
Materials |
stainless steel (1.4404 / 316L); PEEK; PEI; FKM |
Materials (wetted parts) |
PEEK; surface characteristics : Ra < 0,8 / Rz 4 |
Process connection |
threaded connection G 1/2 sealing cone |
Displays / operating elements |
Display |
switching status |
LED, yellow |
operating status |
LED, green |
|
Remarks |
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12; Contacts: gold-plated |