| Product characteristics |
| Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
| Probe length L [mm] |
100…1600 |
| Process connection |
G 3/4 external thread |
| Application |
| Special feature |
Gold-plated contacts |
| Media |
Liquids |
| Dielectric constant of the medium |
≥ 1,8; (for media with a dielectric constant of 1.8…5 (e.g. oils), a coaxial pipe is needed for operation) |
| Recommended media |
water; hydrous media; oils; oil-based media |
| Cannot be used for |
See the operating instructions, chapter “Function and features”. |
| Medium temperature [°C] |
-25…80; (90 < 1 h) |
| Tank pressure [bar] |
-1…16 |
| MAWP (for applications according to CRN) [bar] |
16 |
| Electrical data |
| Operating voltage [V] |
18…30 DC |
| Current consumption [mA] |
< 30 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time [s] |
< 3 |
| Inputs / outputs |
| Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
| Outputs |
| Total number of outputs |
2 |
| Output signal |
switching signal; analogue signal; IO-Link |
| Electrical design |
PNP |
| Number of digital outputs |
1 |
| Output function |
normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] |
2.5 |
| Permanent current rating of switching output DC [mA] |
200 |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4…20, invertible; (scalable) |
| Max. load [Ω] |
500 |
| Analogue voltage output [V] |
0…10, invertible; (scalable) |
| Min. load resistance [Ω] |
2000 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
thermal, pulsed |
| Overload protection |
yes |
| Measuring/setting range |
| Probe length L [mm] |
100…1600 |
| Active range A [mm] |
L-40; (when set to oil and oil based media: L-60) |
| Inactive range I1 / I2 [mm] |
30 / 10; (when set to oil and oil based media: 30 / 30) |
| Sampling rate [Hz] |
4 |
| Setting range |
| Set point SP [mm] |
≥ 15…L-30 |
| Note on setpoint SP |
| when set to oil and oil based media: 35…L-30 |
|
| Reset point rP [mm] |
≥ 10…L-35 |
| Note on reset point rP |
| when set to oil and oil based media: 30…L-35 |
|
| In steps of [mm] |
5 |
| Hysteresis [mm] |
> 5 |
| Accuracy / deviations |
| Repeatability [mm] |
± 5 |
| Measuring error [mm] |
± 7 |
| Offset error [mm] |
5 |
| Resolution [mm] |
1 |
| Zero signal (voltage) [V] |
0 |
| Zero signal (current) [mA] |
4.0 |
| Full signal (voltage) [V] |
10 |
| Full signal (current) [mA] |
20 |
| Temperature drift per 10 K |
± 0.2 |
| Interfaces |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 CDV |
| Profiles |
no profile |
| SIO mode |
yes |
| Required master port type |
A |
| Process data analogue |
1 |
| Process data binary |
1 |
| Min. process cycle time [ms] |
2.3 |
| Supported DeviceIDs |
| Type of operation |
DeviceID |
| Default |
344 |
|
| Operating conditions |
| Ambient temperature [°C] |
-25…60 |
| Storage temperature [°C] |
-40…80 |
| Protection |
IP 67 |
| Mechanical data |
| Weight [g] |
438 |
| Materials |
stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L) ; FKM; PBT; PC; PEI; TPE-V |
| Materials (wetted parts) |
stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR reinforced fibre |
| Process connection |
G 3/4 external thread |
| Displays / operating elements |
| Display |
| Display unit |
3 x LED, green |
| switching status |
1 x LED, yellow |
| level |
alphanumeric display, 4-digit |
| parameter setting |
alphanumeric display, 4-digit |
|
| Remarks |
| Notes |
Please see the technical note under “Downloads” |
| Pack quantity |
1 pcs. |
| Electrical connection |
| Connection |
Connector: 1 x M12; Contacts: gold-plated |