Product characteristics |
Output signal |
analogue signal; (configurable) |
Measuring range |
-0.05…1 bar |
-50…1000 mbar |
-0.73…14.5 psi |
-5…100 kPa |
|
Process connection |
threaded connection G 1 external thread sealing cone |
Application |
Special feature |
Gold-plated contacts |
Measuring element |
ceramic-capacitive pressure measuring cell |
Application |
food and beverage industry |
Media |
viscous media and liquids with suspended particles; liquids and gases |
Medium temperature [°C] |
-25…125; (150 max. 1h) |
Min. bursting pressure |
30000 mbar |
435 psi |
3000 kPa |
|
Pressure rating |
10000 mbar |
145 psi |
1000 kPa |
|
Vacuum resistance [mbar] |
-1000 |
Type of pressure |
relative pressure |
No dead space |
yes |
MAWP (for applications according to CRN) [bar] |
10 |
Electrical data |
Operating voltage [V] |
18…30 DC |
Min. insulation resistance [MΩ] |
100; (500 V DC) |
Protection class |
III |
Reverse polarity protection |
yes |
Integrated watchdog |
yes |
2-wire |
Current consumption [mA] |
3.5…21.5 |
Power-on delay time [s] |
1 |
3-wire |
Current consumption [mA] |
< 45 |
Power-on delay time [s] |
0.5 |
Inputs / outputs |
Number of inputs and outputs |
Number of analogue outputs: 1 |
Outputs |
Total number of outputs |
1 |
Output signal |
analogue signal; (configurable) |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4…20; (scalable) |
Max. load [Ω] |
700; (Ub = 24 V; (Ub – 9 V) / 21.5 mA) |
Short-circuit proof |
yes |
Overload protection |
yes |
Measuring/setting range |
Measuring range |
-0.05…1 bar |
-50…1000 mbar |
-0.73…14.5 psi |
-5…100 kPa |
|
Analogue start point |
-50…800 mbar |
-0.73…11.6 psi |
-5…80 kPa |
|
Analogue end point |
150…1000 mbar |
2.18…14.5 psi |
15…100 kPa |
|
In steps of |
0.5 mbar |
0.01 psi |
0.05 kPa |
|
Factory setting |
ASP = 0.0 bar |
AEP = 1000 mbar |
|
|
Accuracy / deviations |
Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span] |
< ± 0,2 (DIN EN 61298-2); (incl. zero point and span error, non-linearity, hysteresis ; Turn down 1:1) |
Linearity deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
Hysteresis deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
Long-term stability [% of the span] |
< ± 0,1; (Turn down 1:1; per year) |
Temperature coefficient zero point [% of the span / 10 K] |
< ± 0,05; (0…70 °C) |
Temperature coefficient span [% of the span / 10 K] |
< ± 0,15; (0…70 °C) |
Response times |
Damping for the analogue output dAA [s] |
0…4 |
2-wire |
Step response time analogue output [ms] |
30 |
3-wire |
Step response time analogue output [ms] |
7 |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
Profiles |
Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
SIO mode |
no |
Required master port type |
A |
Process data analogue |
3 |
Min. process cycle time [ms] |
3.2 |
Supported DeviceIDs |
Type of operation |
DeviceID |
Default |
668 |
|
Operating conditions |
Ambient temperature [°C] |
-25…80 |
Storage temperature [°C] |
-40…100 |
Protection |
IP 67; IP 68; IP 69K |
Mechanical data |
Weight [g] |
306 |
Materials |
stainless steel (1.4404 / 316L); PBT |
Materials (wetted parts) |
ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
Min. pressure cycles |
100 million |
Tightening torque [Nm] |
20 |
Process connection |
threaded connection G 1 external thread sealing cone |
Displays / operating elements |
Display unit |
mbar; psi; kPa; mWS; inH2O |
Remarks |
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12; Contacts: gold-plated |