Product characteristics |
Output signal |
switching signal; IO-Link; (configurable) |
Measuring range |
0…2.5 bar |
0…2500 mbar |
0…36.3 psi |
0…250 kPa |
|
Process connection |
threaded connection G 1/4 internal thread |
Application |
Special feature |
Gold-plated contacts |
Application |
for industrial applications |
Media |
liquids and gases |
Medium temperature [°C] |
-20…60 |
Min. bursting pressure |
|
Pressure rating |
|
Type of pressure |
relative pressure |
Electrical data |
Operating voltage [V] |
18…36 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] |
< 50 |
Protection class |
III |
Reverse polarity protection |
yes |
Overvoltage protection |
yes; (< 40 V) |
Power-on delay time [s] |
0.3 |
Integrated watchdog |
yes |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2 |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; IO-Link; (configurable) |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2 |
Permanent current rating of switching output DC [mA] |
250 |
Switching frequency DC [Hz] |
< 170 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Measuring/setting range |
Measuring range |
0…2.5 bar |
0…2500 mbar |
0…36.3 psi |
0…250 kPa |
|
Set point SP |
0.02…2.5 bar |
0.4…36.2 psi |
2…250 kPa |
|
Reset point rP |
0.01…2.49 bar |
0.2…36 psi |
1…249 kPa |
|
In steps of |
|
Factory setting |
SP1 = 0.63 bar |
rP1 = 0.58 bar |
|
SP2 = 1.88 bar |
rP2 = 1.83 bar |
|
|
Accuracy / deviations |
Switch point accuracy [% of the span] |
< ± 0,5 |
Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span] |
< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span] |
< ± 0,25 |
Long-term stability [% of the span] |
< ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K] |
0,2; (0…60 °C) |
Temperature coefficient span [% of the span / 10 K] |
0,2; (0…60 °C) |
Response times |
Delay time programmable dS, dr [s] |
0; 0,2…50 |
Software / programming |
Parameter setting options |
hysteresis / window; normally open / normally closed; diagnostic function; switching logic; switch-on/switch-off delay; Damping; Display unit |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 CDV |
Profiles |
no profile |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
1 |
Process data binary |
2 |
Min. process cycle time [ms] |
2.3 |
Supported DeviceIDs |
Type of operation |
DeviceID |
Default |
312 |
|
Operating conditions |
Ambient temperature [°C] |
-20…60 |
Storage temperature [°C] |
-40…100 |
Protection |
IP 65 |
Mechanical data |
Weight [g] |
303 |
Materials |
stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE |
Materials (wetted parts) |
stainless steel (1.4305 / 303); ceramics; FKM |
Min. pressure cycles |
100 million |
Process connection |
threaded connection G 1/4 internal thread |
Restrictor element integrated |
no (can be retrofitted) |
Displays / operating elements |
Display |
Display unit |
3 x LED, green |
switching status |
2 x LED, yellow |
function display |
alphanumeric display, 4-digit |
measured values |
alphanumeric display, 4-digit |
|
Remarks |
Pack quantity |
1 pcs. |
Electrical connection |
|
Connector: 1 x M12; Contacts: gold-plated |