Cảm biến áp suất IFM PN7297 0…1 bar

Product characteristics
Output signal switching signal; IO-Link; (configurable)
Measuring range
 
0…1 bar 0…1000 mbar 0…14.5 psi 0…29.5 inHg 0…100 kPa
Process connection threaded connection 1/4″ NPT internal thread
Application
Special feature Gold-plated contacts
Measuring element ceramic-capacitive pressure measuring cell
Application for industrial applications
Media liquids and gases
Medium temperature [°C] -25…80
Min. bursting pressure
 
30000 mbar 450 psi 880 inHg 3000 kPa
Pressure rating
 
10000 mbar 145 psi 290 inHg 1000 kPa
Type of pressure relative pressure
MAWP (for applications according to CRN)
 
10 bar 10000 mbar 145 psi 290 inHg 1000 kPa
Electrical data
Operating voltage [V] 18…30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA] < 35
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] < 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2
Outputs
Total number of outputs 2
Output signal switching signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 150; (200 (…60 °C) 250 (…40 °C))
Switching frequency DC [Hz] < 170
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
 
0…1 bar 0…1000 mbar 0…14.5 psi 0…29.5 inHg 0…100 kPa
Factory setting / CMPT = 2
Set point SP
 
10…1000 mbar 0.1…14.5 psi 0.2…29.5 inHg 1…100 kPa
Reset point rP
 
5…995 mbar 0.05…14.45 psi 0.1…29.4 inHg 0.5…99.5 kPa
Min. difference between SP and rP
 
5 mbar 0.1 psi 0.2 inHg 0.5 kPa
In steps of
 
5 mbar 0.05 psi 0.1 inHg 0.5 kPa
Status_B High Resolution / CMPT = 3
Set point SP
 
8…1000 mbar 0.12…14.5 psi 0.2…29.5 inHg 0.8…100 kPa
Reset point rP
 
3…995 mbar 0.05…14.43 psi 0.1…29.4 inHg 0.3…99.5 kPa
Min. difference between SP and rP
 
5 mbar 0.08 psi 0.2 inHg 0.5 kPa
In steps of
 
1 mbar 0.01 psi 0.1 inHg 0.1 kPa
Accuracy / deviations
Switch point accuracy [% of the span] < ± 0,5
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span] < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span] < ± 0,25
Long-term stability [% of the span] < ± 0,05; (per 6 months)
Temperature coefficient zero point [% of the span / 10 K] < ± 0,2; (-0…80 °C)
Temperature coefficient span [% of the span / 10 K] < ± 0,2; (-0…80 °C)
Response times
Response time [ms] < 3
Delay time programmable dS, dr [s] 0…50
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
SIO mode yes
Required master port type A; (when pin 2 not connected: B)
Supported DeviceIDs
 
Type of operation DeviceID
Factory setting / CMPT = 2 456
Status_B High Resolution / CMPT = 3 635
Note
 
For further information please see the IODD PDF file under “Downloads”
Factory setting / CMPT = 2
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
Min. process cycle time [ms] 2.3
IO-Link resolution pressure [mbar] 1
IO-Link resolution pressure [MPa]