| Product characteristics | |||||
|---|---|---|---|---|---|
| Number of inputs and outputs | Number of analogue outputs: 1 | ||||
| Measuring range |
|
||||
| Process connection | Clamp DN50 (2″) DIN 32676 (ISO 2852) | ||||
| Installation length EL [mm] | 100 | ||||
| Application | |||||
| Measuring element | 1 x Pt 1000; (to DIN EN 60751, class A) | ||||
| Media | liquids and gases | ||||
| Pressure rating [bar] | 100 | ||||
| Vacuum resistance [mbar] | -1000 | ||||
| Electrical data | |||||
| Operating voltage [V] | 18…32 DC; (“supply class 2” to cULus) | ||||
| Current consumption [mA] | < 50 | ||||
| Protection class | III | ||||
| Reverse polarity protection | yes | ||||
| Power-on delay time [s] | 2 | ||||
| Inputs / outputs | |||||
| Number of inputs and outputs | Number of analogue outputs: 1 | ||||
| Outputs | |||||
| Total number of outputs | 1 | ||||
| Output signal | analogue signal; IO-Link; (configurable) | ||||
| Number of analogue outputs | 1 | ||||
| Analogue current output [mA] | 4…20 | ||||
| Max. load [Ω] | 300 | ||||
| Short-circuit protection | yes | ||||
| Overload protection | yes | ||||
| Measuring/setting range | |||||
| Measuring range |
|
||||
| Factory setting | 0…100 °C | ||||
| Resolution | |||||
| Resolution of analogue output [K] | 0.04 | ||||
| Resolution of display [K] | 0.1 | ||||
| Accuracy / deviations | |||||
| Precision analogue output [K] | ± 0,3 + (± 0,1 % MS) | ||||
| Temperature coefficient [% of the span / 10 K] | 0,1; (in case of deviation from the reference condition 25 °C) | ||||
| Response times | |||||
| Dynamic response T05 / T09 [s] | 1 / 3 | ||||
| Interfaces | |||||
| Communication interface | IO-Link | ||||
| Transmission type | COM2 (38,4 kBaud) | ||||
| IO-Link revision | 1.1 | ||||
| Operating conditions | |||||
| Ambient temperature [°C] | -25…80 | ||||
| Storage temperature [°C] | -40…100 | ||||
| Protection | IP 67; IP 68; IP 69K | ||||
| Mechanical data | |||||
| Weight [g] | 398.5 | ||||
| Materials | stainless steel (1.4404 / 316L); PEI; FKM | ||||
| Materials (wetted parts) | stainless steel (1.4404 / 316L) electropolished | ||||
| Process connection | Clamp DN50 (2″) DIN 32676 (ISO 2852) | ||||
| Surface characteristics Ra/Rz of the wetted parts | Ra: < 0.8 | ||||
| Probe diameter [mm] | 6 | ||||
| Installation length EL [mm] | 100 | ||||
| Displays / operating elements | |||||
| Display |
|
||||
| Remarks | |||||
| Remarks |
|
||||
| Pack quantity | 1 pcs. | ||||
| Electrical connection | |||||
| Connection | Connector: 1 x M12 | ||||