| Product characteristics |
| Output signal |
switching signal; analogue signal; (configurable) |
| Measuring range |
| -0.0124…0.25 bar |
-12.4…250 mbar |
-5…100.4 inH2O |
-1.24…25 kPa |
|
| Process connection |
threaded connection G 1 external thread sealing cone |
| Application |
| Special feature |
Gold-plated contacts |
| Application |
food and beverage industry |
| Installation |
freely rotatable housing 350° |
| Media |
viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature [°C] |
-20…60; (when used outside the hazardous area:; Ambient temperature: -25…85 °C; Medium temperature: -25…125 °C / 145 °C < 1h) |
| Min. bursting pressure |
| 30000 mbar |
12044 inH2O |
3000 kPa |
|
| Pressure rating |
| 6000 mbar |
2400 inH2O |
600 kPa |
|
| Type of pressure |
relative pressure; vacuum |
| Electrical data |
| Operating voltage [V] |
18…32 DC |
| Current consumption [mA] |
< 50 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time [s] |
0.5 |
| Integrated watchdog |
yes |
| Inputs / outputs |
| Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
| Outputs |
| Total number of outputs |
2 |
| Output signal |
switching signal; analogue signal; (configurable) |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
1 |
| Output function |
normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] |
2 |
| Permanent current rating of switching output DC [mA] |
250 |
| Switching frequency DC [Hz] |
6 |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4…20, invertible; (scalable 1:4) |
| Max. load [Ω] |
(Ub – 10 V) / 20 mA |
| Analogue voltage output [V] |
0…10, invertible; (scalable 1:4) |
| Min. load resistance [Ω] |
2000 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Overload protection |
yes |
| Measuring/setting range |
| Measuring range |
| -0.0124…0.25 bar |
-12.4…250 mbar |
-5…100.4 inH2O |
-1.24…25 kPa |
|
| Set point SP |
| -12…250 mbar |
-4.8…100.4 inH2O |
-1.2…25 kPa |
|
| Reset point rP |
| -12.4…249.6 mbar |
-5…100.2 inH2O |
-1.24…24.96 kPa |
|
| Analogue start point |
| -12.4…187.4 mbar |
-5…75.2 inH2O |
-1.24…18.74 kPa |
|
| Analogue end point |
| 50…250 mbar |
20.1…100.4 inH2O |
5…25 kPa |
|
| In steps of |
| 0.2 mbar |
0.1 inH2O |
0.02 kPa |
|
| Accuracy / deviations |
| Switch point accuracy [% of the span] |
< ± 0,2; (Turn down 1:1) |
| Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation [% of the span] |
< ± 0,2; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) |
| Linearity deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
| Hysteresis deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
| Long-term stability [% of the span] |
< ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point [% of the span / 10 K] |
< ± 0,05; (0…70 °C) |
| Temperature coefficient span [% of the span / 10 K] |
< ± 0,15; (0…70 °C) |
| Response times |
| Response time [ms] |
< 100 |
| Damping for the switching output dAP [s] |
0.1…100 |
| Damping for the analogue output dAA [s] |
0.1…100 |
| Step response time analogue output [ms] |
25 |
| Software / programming |
| Parameter setting options |
hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span |
| Operating conditions |
| Ambient temperature [°C] |
-20…60 |
| Storage temperature [°C] |
-40…100 |
| Protection |
IP 65 |
| Mechanical data |
| Weight [g] |
509 |
| Materials |
stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE |
| Materials (wetted parts) |
ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); stainless steel (1.4404 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE; EPDM |
| Min. pressure cycles |
100 million |
| Process connection |
threaded connection G 1 external thread sealing cone |
| Displays / operating elements |
| Display |
| Display unit |
6 x, green |
| switching status |
LED, yellow |
| function display |
alphanumeric display, 4-digit |
| measured values |
alphanumeric display, 4-digit |
|
| Display unit |
mbar; kPa; inH2O; mmWS; % of the span |
| Remarks |
| Pack quantity |
1 pcs. |
| Electrical connection |
| Connection |
Connector: 1 x M12; Contacts: gold-plated |