Cảm biến áp suất IFM PI2307 -50…1000 mbar

Product characteristics
Output signal switching signal; analogue signal; IO-Link; (configurable)
Measuring range
 
-50…1000 mbar -0.73…14.5 psi -5…100 kPa
Process connection Clamp DN50 (2″) DIN 32676 (ISO 2852)
Application
Special feature Gold-plated contacts
Application food and beverage industry
Media viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C] -25…200
Min. bursting pressure
 
30000 mbar 435 psi 3000 kPa
Pressure rating
 
10000 mbar 145 psi 1000 kPa
Type of pressure relative pressure
Electrical data
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Integrated watchdog yes
2-wire
Operating voltage [V] 20…32 DC
Current consumption [mA] 3.6…21
Power-on delay time [s] 1
3-wire
Operating voltage [V] 18…32 DC
Current consumption [mA] < 45
Power-on delay time [s] 0.5
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Number of analogue outputs 1
Analogue current output [mA] 4…20, invertible; (scalable)
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
2-wire
Max. load [Ω] 300
3-wire
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250
Switching frequency DC [Hz] 125
Max. load [Ω] (Ub – 10 V) / 20 mA
Measuring/setting range
Measuring range
 
-50…1000 mbar -0.73…14.5 psi -5…100 kPa
Set point SP
 
-48…1000 mbar -0.7…14.5 psi -4.8…100 kPa
Reset point rP
 
-50…998 mbar -0.73…14.47 psi -0.5…99.8 kPa
Analogue start point
 
-50…750 mbar -0.73…10.88 psi -5…75 kPa
Analogue end point
 
200…1000 mbar 2.9…14.5 psi 20…100 kPa
In steps of
 
1 mbar 0.01 psi 0.1 kPa
Factory setting
 
  SP1 = 250 mbar rP1 = 230 mbar
  SP2 = 750 mbar rP2 = 730 mbar
  ASP = 0 mbar AEP = 1000 mbar
Accuracy / deviations
Switch point accuracy [% of the span] < ± 0,2; (Turn down 1:1)
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span] < ± 0,2; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086)
Linearity deviation [% of the span] < ± 0,15; (Turn down 1:1)
Hysteresis deviation [% of the span] < ± 0,15; (Turn down 1:1)
Long-term stability [% of the span] < ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point [% of the span / 10 K] < ± 0,3; (0…200 °C)
Temperature coefficient span [% of the span / 10 K] < ± 0,15; (0…200 °C)
Response times
Damping for the switching output dAP [s] 0…30
Damping for the analogue output dAA [s] 0.01…99.99
2-wire
Step response time analogue output [ms] 45
3-wire
Min. response time of switching output (dAP) [ms] 3
Step response time analogue output [ms] 7
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.0
SDCI standard IO-Link Communication Specification, Version 1.0, January 2009, Ordner No: 10.002
Profiles no profile
SIO mode yes
Required master port type A
Process data analogue 1
Process data binary 2
Min. process cycle time [ms] 2.3
Supported DeviceIDs
 
Type of operation DeviceID
Default 106
Operating conditions
Ambient temperature [°C] -25…80
Note on ambient temperature
 
Medium temperature: ≤ 160 °C
Ambient temperature [°C] -25…65
Note on ambient temperature
 
Medium temperature: ≤ 200 °C
Storage temperature [°C] -25…100
Protection IP 67; IP 68; IP 69K
Mechanical data
Weight [g] 1205.2
Materials stainless steel (1.4404 / 316L); stainless steel (1.4435 / 316L); PBT; PEI; PFA
Materials (wetted parts) stainless steel (1.4435 / 316L)
Min. pressure cycles 10 million
Process connection Clamp DN50 (2″) DIN 32676 (ISO 2852)