Cảm biến áp suất IFM PI2309 -1000…1000 mbar

Product characteristics
Output signal switching signal; analogue signal; IO-Link; (configurable)
Measuring range
 
-1000…1000 mbar -14.5…14.5 psi -100…100 kPa
Process connection Clamp DN50 (2″) DIN 32676 (ISO 2852)
Application
Special feature Gold-plated contacts
Application food and beverage industry
Media viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C] -25…200
Min. bursting pressure
 
30000 mbar 435 psi 3000 kPa
Pressure rating
 
10000 mbar 145 psi 1000 kPa
Type of pressure relative pressure; vacuum
Electrical data
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Integrated watchdog yes
2-wire
Operating voltage [V] 20…32 DC
Current consumption [mA] 3.6…21
Power-on delay time [s] 1
3-wire
Operating voltage [V] 18…32 DC
Current consumption [mA] < 45
Power-on delay time [s] 0.5
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Number of analogue outputs 1
Analogue current output [mA] 4…20, invertible; (scalable)
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
2-wire
Max. load [Ω] 300
3-wire
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250
Switching frequency DC [Hz] 125
Max. load [Ω] (Ub – 10 V) / 20 mA
Measuring/setting range
Measuring range
 
-1000…1000 mbar -14.5…14.5 psi -100…100 kPa
Set point SP
 
-998…1000 mbar -14.45…14.5 psi -99.8…100 kPa
Reset point rP
 
-1000…998 mbar -14.5…14.45 psi -100…99.8 kPa
Analogue start point
 
-1000…500 mbar -14.5…7.25 psi -100…50 kPa
Analogue end point
 
-500…1000 mbar -7.25…14.5 psi -50…100 kPa
In steps of
 
1 mbar 0.05 psi 0.1 kPa
Factory setting
 
  SP1 = -500 mbar rP1 = -540 mbar
  SP2 = 500 mbar rP2 = 460 mbar
  ASP = -1000 mbar AEP = 1000 mbar
Accuracy / deviations
Switch point accuracy [% of the span] < ± 0,2; (Turn down 1:1)
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span] < ± 0,2; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086)
Linearity deviation [% of the span] < ± 0,15; (Turn down 1:1)
Hysteresis deviation [% of the span] < ± 0,15; (Turn down 1:1)
Long-term stability [% of the span] < ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point [% of the span / 10 K] < ± 0,3; (0…200 °C)
Temperature coefficient span [% of the span / 10 K] < ± 0,15; (0…200 °C)
Response times
Damping for the switching output dAP [s] 0…30
Damping for the analogue output dAA [s] 0.01…99.99
2-wire
Step response time analogue output [ms] 45
3-wire
Min. response time of switching output (dAP) [ms] 3
Step response time analogue output [ms] 7
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.0
SDCI standard IO-Link Communication Specification, Version 1.0, January 2009, Ordner No: 10.002
Profiles no profile
SIO mode yes
Required master port type A
Process data analogue 1
Process data binary 2
Min. process cycle time [ms] 2.3
Supported DeviceIDs
 
Type of operation DeviceID
Default 108
Operating conditions
Ambient temperature [°C] -25…80
Note on ambient temperature
 
Medium temperature: ≤ 160 °C
Ambient temperature [°C] -25…65
Note on ambient temperature
 
Medium temperature: ≤ 200 °C
Storage temperature [°C] -25…100
Protection IP 67; IP 68; IP 69K
Mechanical data
Weight [g] 1047.5
Materials stainless steel (1.4404 / 316L); stainless steel (1.4435 / 316L); PBT; PEI; PFA
Materials (wetted parts) stainless steel (1.4435 / 316L)
Min. pressure cycles 10 million
Process connection Clamp DN50 (2″) DIN 32676 (ISO 2852)

Sản phẩm cùng loại

Gửi tin nhắn
Gọi cho chúng tôi
Chat qua facebook
Chat qua zalo
Văn phòng