Product characteristics
Output signal switching signal; analogue signal; IO-Link; (configurable)
Measuring range
 
0…400 bar 0…5800 psi 0…40 MPa
Process connection threaded connection G 1/4 internal thread (DIN EN ISO 1179-2)
Application
Special feature Gold-plated contacts
Measuring element metallic thin film cell
Application for industrial applications
Media liquids and gases
Medium temperature [°C] -25…80
Min. bursting pressure
 
1700 bar 24650 psi 170 MPa
Pressure rating
 
800 bar 11580 psi 80 Mpa
Vacuum resistance [mbar] -1000
Type of pressure relative pressure
Electrical data
Operating voltage [V] 18…30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA] < 35
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250
Switching frequency DC [Hz] < 500
Number of analogue outputs 1
Analogue current output [mA] 4…20; (scalable 1:5)
Max. load [Ω] 500
Analogue voltage output [V] 0…10; (scalable 1:5)
Min. load resistance [Ω] 2000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
 
0…400 bar 0…5800 psi 0…40 MPa
Analogue start point
 
0…320 bar 0…4640 psi 0…32 MPa
Analogue end point
 
80…400 bar 1160…5800 psi 8…40 MPa
Factory setting / CMPT = 2
Set point SP
 
2.5…400 bar 40…5800 psi 0.25…40 MPa
Reset point rP
 
1…398.5 bar 10…5780 psi 0.1…39.85 MPa
Min. difference between SP and rP
 
2 bar 30 psi 0.2 MPa
In steps of
 
0.5 bar 10 psi 0.05 MPa
Status_B High Resolution / CMPT = 3
Set point SP
 
2.5…400 bar 37…5802 psi 0.25…40 MPa
Reset point rP
 
0.9…398.4 bar 13…5778 psi 0.09…39.84 MPa
Min. difference between SP and rP
 
1.7 bar 24 psi 0.17 MPa
In steps of
 
0.1 bar 1 psi 0.01 MPa
Accuracy / deviations
Notes on the accuracy / deviation switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
Switch point accuracy [% of the span] < ± 0,4; (Turn down 1:1)
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span] < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span] < ± 0,1; (Turn down 1:1)
Long-term stability [% of the span] < ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point [% of the span / 10 K] 0,2; (-25…80 °C)
Temperature coefficient span [% of the span / 10 K] 0,2; (-25…80 °C)
Response times
Response time [ms] < 1.5
Delay time programmable dS, dr [s] 0…50
Damping for the switching output dAP [s] 0…4
Damping for the analogue output dAA [s] 0…4
Max. response time analogue output [ms] 3
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
SIO mode yes
Required master port type A; (wenn PIN 2 nicht verbunden: B)
Supported DeviceIDs
 
Type of operation DeviceID
Factory setting / CMPT = 2 459
Status_B High Resolution / CMPT = 3 638
Note
 
For further information please see the IODD PDF file under “Downloads”
Factory setting / CMPT = 2
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
Min. process cycle time [ms]