Product characteristics |
Output signal |
switching signal; analogue signal; IO-Link; (configurable) |
Measuring range |
0…100 bar |
0…1450 psi |
0…10 MPa |
|
Process connection |
threaded connection G 1/4 internal thread M6 I |
Application |
Special feature |
Gold-plated contacts |
Measuring element |
ceramic-capacitive pressure measuring cell |
Application |
for industrial applications |
Media |
Liquids |
Conditionally suitable for |
use in gases at pressures > 25 bar only on request |
Medium temperature [°C] |
-25…80 |
Min. bursting pressure |
|
Pressure rating |
|
Vacuum resistance [mbar] |
-1000 |
Type of pressure |
relative pressure |
Electrical data |
Operating voltage [V] |
18…30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] |
< 35 |
Min. insulation resistance [MΩ] |
100; (500 V DC) |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
< 0.3 |
Integrated watchdog |
yes |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; analogue signal; IO-Link; (configurable) |
Electrical design |
PNP |
Number of digital outputs |
1 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
150; (200 (…60 °C) 250 (…40 °C)) |
Switching frequency DC [Hz] |
< 170 |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4…20 |
Max. load [Ω] |
500 |
Analogue voltage output [V] |
0…10 |
Min. load resistance [Ω] |
2000 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring/setting range |
Measuring range |
0…100 bar |
0…1450 psi |
0…10 MPa |
|
Factory setting / CMPT = 2 |
Set point SP |
1…100 bar |
10…1450 psi |
0.1…10 MPa |
|
Reset point rP |
0.5…99.5 bar |
5…1445 psi |
0.05…9.95 MPa |
|
Min. difference between SP and rP |
|
In steps of |
|
Status_B High Resolution / CMPT = 3 |
Set point SP |
0.8…100 bar |
12…1450 psi |
0.08…10 MPa |
|
Reset point rP |
0.3…99.5 bar |
5…1443 psi |
0.03…9.95 MPa |
|
Min. difference between SP and rP |
|
In steps of |
|
Accuracy / deviations |
Switch point accuracy [% of the span] |
< ± 0,5 |
Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span] |
< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span] |
< ± 0,25 |
Long-term stability [% of the span] |
< ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K] |
< ± 0,2; (-25…80 °C) |
Temperature coefficient span [% of the span / 10 K] |
< ± 0,2; (-25…80 °C) |
Response times |
Response time [ms] |
< 3 |
Delay time programmable dS, dr [s] |
0…50 |
Damping for the switching output dAP [s] |
0…4 |
Damping for the analogue output dAA [s] |
0…4 |
Max. response time analogue output [ms] |
3 |
Software / programming |
Parameter setting options |
hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
1 |
Process data binary |
1 |
Supported DeviceIDs |
Type of operation |
DeviceID |
Factory setting / CMPT = 2 |
429 |
Status_B High Resolution / CMPT = 3 |
608 |
|
Note |
For further information please see the IODD PDF file under “Downloads” |
|
Factory setting / CMPT = 2 |
Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
Min. process cycle time [ms] |
2.3 |
IO-Link resolution pressure [bar] |
0.1 |
IO-Link resolution pressure [MPa] |
0.01 |
IO-Link process data (cyclical) |
function |
bit length |
Sản phẩm cùng loại
Chat qua zalo
Để lại thông tin - Nhận giá ưu đãi
Gọi cho CÔNG NGHIỆP VÀ TỰ ĐỘNG HÓA COZIC để nhận tư vấn tốt nhất
Địa chỉ - CÔNG NGHIỆP VÀ TỰ ĐỘNG HÓA COZIC
78 Hoà Minh 1 - Hoà Minh - Liên Chiểu - Đà Nẵng - Việt Nam
Văn phòng - CÔNG NGHIỆP VÀ TỰ ĐỘNG HÓA COZIC
VP: 16 Vũ Huy Tấn - Hoà Hiệp Nam - Liên Chiểu- Đà Nẵng- Việt Nam
Thông báo sẽ tự động tắt sau 5 giây ...
|