Product characteristics |
Output signal |
switching signal; IO-Link; (configurable) |
Measuring range |
-1…10 bar |
-14.5…145 psi |
-100…1000 kPa |
-0.1…1 MPa |
|
Process connection |
threaded connection 1/4″ NPT internal thread |
Application |
Special feature |
Gold-plated contacts |
Measuring element |
ceramic-capacitive pressure measuring cell |
Application |
for industrial applications |
Media |
liquids and gases |
Medium temperature [°C] |
-25…80 |
Min. bursting pressure |
|
Pressure rating |
|
Type of pressure |
relative pressure; vacuum |
MAWP (for applications according to CRN) [bar] |
50 |
Electrical data |
Operating voltage [V] |
18…30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] |
< 35 |
Min. insulation resistance [MΩ] |
100; (500 V DC) |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
< 0.3 |
Integrated watchdog |
yes |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2 |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; IO-Link; (configurable) |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
150; (200 (…60 °C) 250 (…40 °C)) |
Switching frequency DC [Hz] |
< 170 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring/setting range |
Measuring range |
-1…10 bar |
-14.5…145 psi |
-100…1000 kPa |
-0.1…1 MPa |
|
Factory setting / CMPT = 2 |
Set point SP |
-0.9…10 bar |
-13.5…145 psi |
-0.09…1 MPa |
|
Reset point rP |
-0.95…9.95 bar |
-14…144.5 psi |
-0.095…0.995 MPa |
|
Min. difference between SP and rP |
|
In steps of |
0.05 bar |
0.5 psi |
0.005 MPa |
|
Status_B High Resolution / CMPT = 3 |
Set point SP |
-0.92…10 bar |
-13.3…145 psi |
-0.092…1 MPa |
|
Reset point rP |
-0.97…9.95 bar |
-14…144.3 psi |
-0.097…9.995 MPa |
|
Min. difference between SP and rP |
0.05 bar |
0.8 psi |
0.005 MPa |
|
In steps of |
0.01 bar |
0.1 psi |
0.001 MPa |
|
Accuracy / deviations |
Switch point accuracy [% of the span] |
< ± 0,5 |
Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span] |
< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span] |
< ± 0,25 |
Long-term stability [% of the span] |
< ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K] |
< ± 0,2; (-0…80 °C) |
Temperature coefficient span [% of the span / 10 K] |
< ± 0,2; (-0…80 °C) |
Response times |
Response time [ms] |
< 3 |
Delay time programmable dS, dr [s] |
0…50 |
Software / programming |
Parameter setting options |
hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
SIO mode |
yes |
Required master port type |
A; (when pin 2 not connected: B) |
Supported DeviceIDs |
Type of operation |
DeviceID |
Factory setting / CMPT = 2 |
454 |
Status_B High Resolution / CMPT = 3 |
632 |
|
Note |
For further information please see the IODD PDF file under “Downloads” |
|
Factory setting / CMPT = 2 |
Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
Min. process cycle time [ms] |
2.3 |
IO-Link resolution pressure [bar] |
0.01 |
IO-Link resolution pressure [MPa] |
0.001 |
IO-Link process data (cyclical) |
function |
bit length |
pressure |
14 |
binary switching information |
2 |
|
IO-Link functions (acyclical) |
application specific tag |
Status_B High Resolution / CMPT = 3 |
Profiles |
Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
Min. process cycle time [ms] |
3 |
IO-Link resolution pressure [bar] |
0.005 |
IO-Link resolution pressure [MPa] |
0.0005 |
IO-Link process data (cyclical) |
Sản phẩm cùng loại
Chat qua zalo
Để lại thông tin - Nhận giá ưu đãi
Gọi cho CÔNG NGHIỆP VÀ TỰ ĐỘNG HÓA COZIC để nhận tư vấn tốt nhất
Địa chỉ - CÔNG NGHIỆP VÀ TỰ ĐỘNG HÓA COZIC
78 Hoà Minh 1 - Hoà Minh - Liên Chiểu - Đà Nẵng - Việt Nam
Văn phòng - CÔNG NGHIỆP VÀ TỰ ĐỘNG HÓA COZIC
VP: 16 Vũ Huy Tấn - Hoà Hiệp Nam - Liên Chiểu- Đà Nẵng- Việt Nam
Thông báo sẽ tự động tắt sau 5 giây ...
|