Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Process connection |
diameter Ø 8 mm |
Application |
Special feature |
Gold-plated contacts |
Media |
water; glycol solutions; air; oils |
Note on media |
low-viscosity oils with viscosity: ≤ 40 mm²/s (104 °F) |
high-viscosity oils with viscosity: > 40 mm²/s (104 °F) |
|
Medium temperature [°F] |
-4…212 |
Pressure rating [bar] |
50 |
Pressure rating [psi] |
725 |
MAWP (for applications according to CRN) [bar] |
50 |
Electrical data |
Operating voltage [V] |
18…30 DC |
Current consumption [mA] |
< 100 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
10 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; analogue signal; frequency signal; IO-Link; (configurable) |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
250 |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4…20; (scalable) |
Max. load [Ω] |
350 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Frequency of the output [Hz] |
0…1000 |
Measuring/setting range |
Probe length L [mm] |
200 |
Operating mode |
relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended) |
Note on factory setting |
|
Liquids |
Setting range [ft/s] |
0…19.5 |
Greatest sensitivity [ft/s] |
0.15…9.85 |
Gases |
Setting range [ft/s] |
0…656 |
Greatest sensitivity [ft/s] |
6…328 |
Temperature monitoring |
Measuring range [°F] |
-4…212 |
Resolution [°F] |
0.5 |
Accuracy / deviations |
Flow monitoring |
Temperature drift [cm/s x 1/K] |
0,01 fps x 1/K (< 68 °F; > 158 °F) |
Temperature gradient [K/min] |
100 |
Accuracy |
± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions :; water: 68…158 °F; inlet length: 5 ft; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.) |
Repeatability |
0,05 m/s; (water; flow velocity: 0,05…3 m/s) |
Temperature monitoring |
Temperature drift |
± 0,003 K/°F |
Accuracy [K] |
± 0,3 / ± 1; (water; flow velocity: 1…9,85 fps / air; flow velocity: > 32,8 fps) |
Response times |
Flow monitoring |
Response time [s] |
0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09) |
Temperature monitoring |
Dynamic response T05 / T09 [s] |
1,5 (T09); (water; flow velocity: 1…9,85 fps) |
Software / programming |
Parameter setting options |
hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
2 |
Process data binary |
2 |
Min. process cycle time [ms] |
3 |
Supported DeviceIDs |
Type of operation |
DeviceID |
Factory setting / ModE = (REL) |
537 |
ModE = (LIQU) |
544 |
ModE = (GAS) |
551 |
|
Operating conditions |
Ambient temperature [°F] |
-40…176 |
Storage temperature [°F] |
-40…212 |
Protection |
IP 65; IP 67 |
Mechanical data |
Weight [g] |
344.5 |
Materials |
stainless steel (1.4404 / 316L); PBT-GF20; PBT-GF30 |
Materials (wetted parts) |
stainless steel (1.4404 / 316L) |
Process connection |
diameter Ø 8 mm |
Displays / operating elements |
Display |
Display unit |
6 x LED, green (%, fps, gpm, cfm, °F, 10³) |
switching status |
2 x LED, yellow |
measured values |
alphanumeric display, red/green 4-digit |
|
Remarks |
Remarks |
MW = measured value |
MEW = Final value of the measuring range |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12; Contacts: gold-plated |