| Product characteristics |
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
| Process connection |
threaded connection 1/2″ NPT |
| Application |
| Special feature |
Gold-plated contacts |
| Media |
water; glycol solutions; air; oils |
| Note on media |
| low-viscosity oils with viscosity: ≤ 40 mm²/s (104 °F) |
| high-viscosity oils with viscosity: > 40 mm²/s (104 °F) |
|
| Medium temperature [°F] |
-4…194 |
| Pressure rating [bar] |
100 |
| Pressure rating [psi] |
1450 |
| MAWP (for applications according to CRN) [bar] |
100 |
| Electrical data |
| Operating voltage [V] |
18…30 DC |
| Current consumption [mA] |
< 100 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time [s] |
10 |
| Inputs / outputs |
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
| Outputs |
| Total number of outputs |
2 |
| Output signal |
switching signal; analogue signal; frequency signal; IO-Link; (configurable) |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] |
2.5 |
| Permanent current rating of switching output DC [mA] |
250 |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4…20; (scalable) |
| Max. load [Ω] |
350 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Overload protection |
yes |
| Frequency of the output [Hz] |
0…1000 |
| Measuring/setting range |
| Probe length L [mm] |
26.6 |
| Operating mode |
relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended) |
| Note on factory setting |
|
| Liquids |
| Setting range [ft/s] |
0…19.5 |
| Greatest sensitivity [ft/s] |
0.15…9.85 |
| Gases |
| Setting range [ft/s] |
0…656 |
| Greatest sensitivity [ft/s] |
6…328 |
| Temperature monitoring |
| Measuring range [°F] |
-4…194 |
| Resolution [°F] |
0.5 |
| Accuracy / deviations |
| Flow monitoring |
| Temperature drift [cm/s x 1/K] |
0,01 fps x 1/K (< 68 °F; > 158 °F) |
| Temperature gradient [K/min] |
100 |
| Accuracy |
± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions :; water: 68…158 °F; inlet length: 5 ft; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.) |
| Repeatability |
0,05 m/s; (water; flow velocity: 0,05…3 m/s) |
| Temperature monitoring |
| Temperature drift |
± 0,003 K/°F |
| Accuracy [K] |
± 0,3 / ± 1; (water; flow velocity: 1…9,85 fps / air; flow velocity: > 32,8 fps) |
| Response times |
| Flow monitoring |
| Response time [s] |
0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09) |
| Temperature monitoring |
| Dynamic response T05 / T09 [s] |
1,5 (T09); (water; flow velocity: 1…9,85 fps) |
| Software / programming |
| Parameter setting options |
hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour |
| Interfaces |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| SIO mode |
yes |
| Required master port type |
A |
| Process data analogue |
2 |
| Process data binary |
2 |
| Min. process cycle time [ms] |
3 |
| Supported DeviceIDs |
| Type of operation |
DeviceID |
| Factory setting / ModE = (REL) |
537 |
| ModE = (LIQU) |
544 |
| ModE = (GAS) |
551 |
|
| Operating conditions |
| Ambient temperature [°F] |
-40…176 |
| Storage temperature [°F] |
-40…212 |
| Protection |
IP 65; IP 67 |
| Mechanical data |
| Weight [g] |
277.5 |
| Materials |
stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30 |
| Materials (wetted parts) |
stainless steel (1.4404 / 316L) |
| Process connection |
threaded connection 1/2″ NPT |
| Displays / operating elements |
| Display |
| Display unit |
6 x LED, green (%, fps, gpm, cfm, °F, 10³) |
| switching status |
2 x LED, yellow |
| measured values |
alphanumeric display, red/green 4-digit |
|
| Remarks |
| Remarks |
| MW = measured value |
| MEW = Final value of the measuring range |
|
| Pack quantity |
1 pcs. |
| Electrical connection |
| Connection |
Connector: 1 x M12; Contacts: gold-plated |