| Product characteristics |
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
| Process connection |
threaded connection 3/4″ NPT |
| Temperature monitoring |
| Measuring range [°F] |
14…212 |
| Application |
| Special feature |
Gold-plated contacts |
| Application |
for industrial applications |
| Media |
water; glycol solutions; coolants; oil |
| Note on media |
| oil 1 with viscosity: 10 mm²/s (40 °C) |
| oil 2 with viscosity: 46 mm²/s (40 °C) |
|
| Medium temperature [°F] |
14…212 |
| Pressure rating [bar] |
40 |
| Pressure rating [Mpa] |
4 |
| MAWP (for applications according to CRN) [bar] |
40 |
| Electrical data |
| Operating voltage [V] |
18…30 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA] |
< 50 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time [s] |
< 3 |
| Inputs / outputs |
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
| Outputs |
| Total number of outputs |
2 |
| Output signal |
switching signal; analogue signal; frequency signal; IO-Link; (configurable) |
| Number of digital outputs |
2 |
| Output function |
normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] |
2 |
| Permanent current rating of switching output DC [mA] |
150; (per output 2 x 200 (…60 °C); 2 x 250 (…40 °C)) |
| Switching cycles (mechanical) |
10 million |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4…20 |
| Max. load [Ω] |
500 |
| Short-circuit protection |
yes |
| Overload protection |
yes |
| Frequency of the output [Hz] |
0…10000 |
| Measuring/setting range |
| Measuring range |
|
| Display range |
|
| Resolution |
|
| Set point SP |
|
| Reset point rP |
|
| Frequency end point, FEP |
|
| In steps of |
|
| Frequency at the end point FRP [Hz] |
10…10000 |
| Measuring dynamics |
1:50 |
| Temperature monitoring |
| Measuring range [°F] |
14…212 |
| Display range [°F] |
-26…252 |
| Resolution [°F] |
2 |
| Set point SP [°F] |
16…212 |
| In steps of [°F] |
2 |
| Frequency start point, FSP [°F] |
14…172 |
| Frequency end point, FEP [°F] |
54…212 |
| Frequency at the end point FRP [Hz] |
10…10000 |
| Accuracy / deviations |
| Flow monitoring |
| Accuracy (in the measuring range) |
± (4 % MW + 1 % MEW); (Q > 1 l/min; medium and operating temperature: +22 °C ± 4K) |
| Repeatability |
± 1 % MEW |
| Temperature monitoring |
| Temperature drift |
0,029 °C / K |
| Accuracy [K] |
3 K (25°C; Q > 1 l/min) |
| Response times |
| Flow monitoring |
| Response time [s] |
0.01 |
| Damping for the switching output dAP [s] |
0…5 |
| Damping for the analogue output dAA [s] |
0…5 |
| Temperature monitoring |
| Dynamic response T05 / T09 [s] |
T09 = 120 (Q > 1 l/min) |
| Software / programming |
| Parameter setting options |
hysteresis / window; normally open / normally closed; switching logic; current output; medium selection; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour |
| Interfaces |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 CDV |
| Profiles |
Smart Sensor: Process Data Variable; Device Identification |
| SIO mode |
yes |
| Required master port type |
A |
| Process data analogue |
2 |
| Process data binary |
2 |
| Min. process cycle time [ms] |
5 |
| Supported DeviceIDs |
| Type of operation |
DeviceID |
| Default |
567 |
|
| Operating conditions |
| Ambient temperature [°F] |
32…140 |
| Note on ambient temperature |
| medium temperature < 176 °F |
| medium temperature < 212 °F: 32…104 °F |
|
| Storage temperature [°F] |
5…176 |
| Protection |
IP 65; IP 67 |
| Mechanical data |
| Weight [g] |
693 |
| Materials |
stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated |
| Materials (wetted parts) |
stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM |
| Process connection |
threaded connection 3/4″ NPT |
| Displays / operating elements |
| Display |
| Display unit |
3 x LED, green |
| switching status |
2 x LED, yellow |
| measured values |
alphanumeric display, red/green 4-digit |
| programming |
alphanumeric display, 4-digit |
|
| Remarks |
| Remarks |
| Recommendation: use a 200-micron filter. |
| All data refer to water (68 °F). |
| MW = measured value |
| MEW = Final value of the measuring range |
|
| Pack quantity |
1 pcs. |
| Electrical connection |
| Connection |
Connector: 1 x M12; Contacts: gold-plated |