Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Process connection |
threaded connection 3/4″ NPT |
Temperature monitoring |
Measuring range [°F] |
14…212 |
Application |
Special feature |
Gold-plated contacts |
Application |
for industrial applications |
Media |
water; glycol solutions; coolants; oil |
Note on media |
oil 1 with viscosity: 10 mm²/s (40 °C) |
oil 2 with viscosity: 46 mm²/s (40 °C) |
|
Medium temperature [°F] |
14…212 |
Pressure rating [bar] |
40 |
Pressure rating [Mpa] |
4 |
MAWP (for applications according to CRN) [bar] |
40 |
Electrical data |
Operating voltage [V] |
18…30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] |
< 50 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
< 3 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; analogue signal; frequency signal; IO-Link; (configurable) |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2 |
Permanent current rating of switching output DC [mA] |
150; (per output 2 x 200 (…60 °C); 2 x 250 (…40 °C)) |
Switching cycles (mechanical) |
10 million |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4…20 |
Max. load [Ω] |
500 |
Short-circuit protection |
yes |
Overload protection |
yes |
Frequency of the output [Hz] |
0…10000 |
Measuring/setting range |
Measuring range |
|
Display range |
|
Resolution |
|
Set point SP |
|
Reset point rP |
|
Frequency end point, FEP |
|
In steps of |
|
Frequency at the end point FRP [Hz] |
10…10000 |
Measuring dynamics |
1:50 |
Temperature monitoring |
Measuring range [°F] |
14…212 |
Display range [°F] |
-26…252 |
Resolution [°F] |
2 |
Set point SP [°F] |
16…212 |
In steps of [°F] |
2 |
Frequency start point, FSP [°F] |
14…172 |
Frequency end point, FEP [°F] |
54…212 |
Frequency at the end point FRP [Hz] |
10…10000 |
Accuracy / deviations |
Flow monitoring |
Accuracy (in the measuring range) |
± (4 % MW + 1 % MEW); (Q > 1 l/min; medium and operating temperature: +22 °C ± 4K) |
Repeatability |
± 1 % MEW |
Temperature monitoring |
Temperature drift |
0,029 °C / K |
Accuracy [K] |
3 K (25°C; Q > 1 l/min) |
Response times |
Flow monitoring |
Response time [s] |
0.01 |
Damping for the switching output dAP [s] |
0…5 |
Damping for the analogue output dAA [s] |
0…5 |
Temperature monitoring |
Dynamic response T05 / T09 [s] |
T09 = 120 (Q > 1 l/min) |
Software / programming |
Parameter setting options |
hysteresis / window; normally open / normally closed; switching logic; current output; medium selection; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 CDV |
Profiles |
Smart Sensor: Process Data Variable; Device Identification |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
2 |
Process data binary |
2 |
Min. process cycle time [ms] |
5 |
Supported DeviceIDs |
Type of operation |
DeviceID |
Default |
567 |
|
Operating conditions |
Ambient temperature [°F] |
32…140 |
Note on ambient temperature |
medium temperature < 176 °F |
medium temperature < 212 °F: 32…104 °F |
|
Storage temperature [°F] |
5…176 |
Protection |
IP 65; IP 67 |
Mechanical data |
Weight [g] |
693 |
Materials |
stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated |
Materials (wetted parts) |
stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM |
Process connection |
threaded connection 3/4″ NPT |
Displays / operating elements |
Display |
Display unit |
3 x LED, green |
switching status |
2 x LED, yellow |
measured values |
alphanumeric display, red/green 4-digit |
programming |
alphanumeric display, 4-digit |
|
Remarks |
Remarks |
Recommendation: use a 200-micron filter. |
All data refer to water (68 °F). |
MW = measured value |
MEW = Final value of the measuring range |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12; Contacts: gold-plated |