| Product characteristics |
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
| Measuring range |
|
| Process connection |
threaded connection G 2 DN50 flat seal |
| Application |
| Special feature |
Gold-plated contacts |
| Application |
totaliser function; empty pipe detection; for industrial applications |
| Installation |
connection to pipe by means of an adapter |
| Media |
conductive liquids; water; hydrous media |
| Note on media |
| conductivity: ≥ 20 µS/cm |
| viscosity: < 70 mm²/s (40 °C) |
|
| Medium temperature [°F] |
14…158 |
| Pressure rating [bar] |
16 |
| Pressure rating [psi] |
232 |
| MAWP (for applications according to CRN) [bar] |
16.5 |
| Electrical data |
| Operating voltage [V] |
18…32 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA] |
< 150 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time [s] |
5 |
| Inputs / outputs |
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
| Inputs |
| Inputs |
counter reset |
| Outputs |
| Total number of outputs |
2 |
| Output signal |
switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable) |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] |
2 |
| Permanent current rating of switching output DC [mA] |
250; (per output) |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4…20; (scalable) |
| Max. load [Ω] |
500 |
| Analogue voltage output [V] |
0…10; (scalable) |
| Min. load resistance [Ω] |
2000 |
| Pulse output |
flow rate meter |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Overload protection |
yes |
| Frequency of the output [Hz] |
0.1…10000 |
| Measuring/setting range |
| Measuring range |
|
| Display range |
| -11520…11520 gph |
-190…190 gpm |
|
| Resolution |
|
| Set point SP |
|
| Reset point rP |
| 80…9550 gph |
1.3…159.2 gpm |
|
| Analogue start point ASP |
|
| Analogue end point AEP |
|
| Low flow cut-off LFC |
|
| In steps of |
|
| Measuring dynamics |
1:120 |
| Volumetric flow quantity monitoring |
| Pulse value |
0.02…160 E06 gal |
| In steps of |
0.02 gal |
| Pulse length [s] |
0,008…2 |
| Temperature monitoring |
| Measuring range [°F] |
-4…176 |
| Display range [°F] |
-40…212 |
| Resolution [°F] |
0.5 |
| Set point SP [°F] |
-2…176 |
| Reset point rP [°F] |
-3…175 |
| Analogue start point [°F] |
-4…140 |
| Analogue end point [°F] |
32…176 |
| In steps of [°F] |
0.5 |
| Accuracy / deviations |
| Flow monitoring |
| Accuracy (in the measuring range) |
± (0,8 % MW + 0,5 % MEW) |
| Repeatability |
± 0,2% MEW |
| Temperature monitoring |
| Temperature drift |
± 0,0185 °F / K |
| Accuracy [K] |
± 1 (77 °F; Q > 4 gpm) |
| Response times |
| Flow monitoring |
| Response time [s] |
0.35; (dAP = 0) |
| Delay time programmable dS, dr [s] |
0…50 |
| Damping for the switching output dAP [s] |
0…5 |
| Temperature monitoring |
| Dynamic response T05 / T09 [s] |
T09 = 3 (Q > 4 gpm) |
| Software / programming |
| Parameter setting options |
Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/frequency/pulse output; start-up delay; display can be deactivated; Display unit; empty pipe detection |
| Interfaces |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 CDV |
| Profiles |
Smart Sensor: Process Data Variable; Device Identification |
| SIO mode |
yes |
| Required master port type |
A |
| Process data analogue |
3 |
| Process data binary |
2 |
| Min. process cycle time [ms] |
5 |
| Supported DeviceIDs |
| Type of operation |
DeviceID |
| Default |
390 |
|
| Operating conditions |
| Ambient temperature [°F] |
14…140 |
| Storage temperature [°F] |
-13…176 |
| Protection |
IP 65; IP 67 |
| Mechanical data |
| Weight [g] |
3175.15 |
| Materials |
stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U |
| Materials (wetted parts) |
stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKM |
| Process connection |
threaded connection G 2 DN50 flat seal |
| Displays / operating elements |
| Display |
Sản phẩm cùng loại
Chat qua zalo
Để lại thông tin - Nhận giá ưu đãi
Gọi cho CÔNG NGHIỆP VÀ TỰ ĐỘNG HÓA COZIC để nhận tư vấn tốt nhất
Địa chỉ - CÔNG NGHIỆP VÀ TỰ ĐỘNG HÓA COZIC
78 Hoà Minh 1 - Hoà Minh - Liên Chiểu - Đà Nẵng - Việt Nam
Văn phòng - CÔNG NGHIỆP VÀ TỰ ĐỘNG HÓA COZIC
VP: 16 Vũ Huy Tấn - Hoà Hiệp Nam - Liên Chiểu- Đà Nẵng- Việt Nam
Thông báo sẽ tự động tắt sau 5 giây ...
|