Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Measuring range [ml/min] |
5…3000 |
Process connection |
threaded connection G 1/4 DN6 flat seal |
Application |
Special feature |
Gold-plated contacts |
Application |
totaliser function; for industrial applications |
Installation |
connection to pipe by means of an adapter |
Media |
conductive liquids; water; hydrous media |
Note on media |
conductivity: ≥ 20 µS/cm |
viscosity: < 70 mm²/s (40 °C) |
|
Medium temperature [°C] |
0…60 |
Pressure rating [bar] |
10 |
Pressure rating [Mpa] |
1.2 |
MAWP (for applications according to CRN) [bar] |
5.5 |
Electrical data |
Operating voltage [V] |
18…30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] |
< 80 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
5 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Inputs |
Inputs |
counter reset |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2 |
Permanent current rating of switching output DC [mA] |
200 |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4…20; (scalable) |
Max. load [Ω] |
500 |
Analogue voltage output [V] |
0…10; (scalable) |
Min. load resistance [Ω] |
2000 |
Pulse output |
flow rate meter |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring/setting range |
Measuring range [ml/min] |
5…3000 |
Display range [ml/min] |
-1999…3600 |
Resolution [ml/min] |
1 |
Set point SP [ml/min] |
20…3000 |
Reset point rP [ml/min] |
5…2984 |
Analogue start point ASP [ml/min] |
0…2400 |
Analogue end point AEP [ml/min] |
600…3000 |
Low flow cut-off LFC [ml/min] |
< 60 |
Volumetric flow quantity monitoring |
Pulse value |
0.001…3000 l |
Pulse length [s] |
0,008…2 |
Temperature monitoring |
Measuring range [°C] |
-20…80 |
Resolution [°C] |
0.2 |
Set point SP [°C] |
-19.2…80 |
Reset point rP [°C] |
-19.6…79.6 |
Analogue start point [°C] |
-20…60 |
Analogue end point [°C] |
0…80 |
In steps of [°C] |
0.2 |
Accuracy / deviations |
Flow monitoring |
Accuracy (in the measuring range) |
± (2 % MW + 0,5 % MEW) |
Repeatability |
± 0,2 % MEW |
Temperature monitoring |
Accuracy [K] |
± 2,5 (Q > 0,5 l/min) |
Response times |
Flow monitoring |
Response time [s] |
0.15; (dAP = 0, T19) |
Delay time programmable dS, dr [s] |
0…50 |
Damping for the switching output dAP [s] |
0…5 |
Temperature monitoring |
Dynamic response T05 / T09 [s] |
T09 = 40 (Q > 1 l/min) |
Software / programming |
Parameter setting options |
Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
3 |
Process data binary |
2 |
Min. process cycle time [ms] |
4 |
Supported DeviceIDs |
Type of operation |
DeviceID |
Default |
671 |
|
Operating conditions |
Ambient temperature [°C] |
-10…60 |
Storage temperature [°C] |
-25…80 |
Protection |
IP 67 |
Mechanical data |
Weight [g] |
537 |
Materials |
stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE |
Materials (wetted parts) |
stainless steel (1.4404 / 316L); PEEK; EPDM |
Process connection |
threaded connection G 1/4 DN6 flat seal |
Displays / operating elements |
Display |
Display unit |
6 x LED, green (ml/min, l/h, l, m³, °C, 10³) |
switching status |
2 x LED, yellow |
measured values |
alphanumeric display, 4-digit |
programming |
alphanumeric display, 4-digit |
|
Remarks |
Remarks |
MW = measured value |
MEW = Final value of the measuring range |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12; Contacts: gold-plated |