| Product characteristics |
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
| Measuring range [l/min] |
0.1…75 |
| Process connection |
Rc 3/4 DN20 |
| Application |
| Special feature |
Gold-plated contacts |
| Media |
conductive liquids; water; hydrous media |
| Note on media |
| conductivity: ≥ 20 µS/cm |
| viscosity: < 70 mm²/s (40 °C) |
|
| Medium temperature [°C] |
-20…90 |
| Pressure rating [bar] |
16 |
| Pressure rating [Mpa] |
1.6 |
| Electrical data |
| Operating voltage [V] |
18…30 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA] |
< 80 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time [s] |
5 |
| Inputs / outputs |
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
| Inputs |
| Inputs |
counter reset |
| Outputs |
| Total number of outputs |
2 |
| Output signal |
switching signal; analogue signal; pulse signal; IO-Link; frequency signal; (configurable) |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] |
2 |
| Permanent current rating of switching output DC [mA] |
100 |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4…20; (scalable) |
| Max. load [Ω] |
500 |
| Pulse output |
flow rate meter |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Overload protection |
yes |
| Measuring/setting range |
| Measuring range [l/min] |
0.1…75 |
| Display range [l/min] |
-90…90 |
| Resolution [l/min] |
0.1 |
| Set point SP [l/min] |
0.5…75 |
| Reset point rP [l/min] |
0.1…74.6 |
| Analogue start point ASP [l/min] |
0…59.9 |
| Analogue end point AEP [l/min] |
15.1…75 |
| Low flow cut-off LFC [l/min] |
0.1…3.8 |
| Frequency end point, FEP [l/min] |
15.1…75 |
| Frequency at the end point FRP [Hz] |
1…10000 |
| Volumetric flow quantity monitoring |
| Pulse length [s] |
0.003…2 |
| Pulse value |
0.001…99990000 I |
| Temperature monitoring |
| Measuring range [°C] |
-20…90 |
| Display range [°C] |
-42…112 |
| Resolution [°C] |
0.1 |
| Set point SP [°C] |
-19.6…90 |
| Reset point rP [°C] |
-20…89.6 |
| Analogue start point [°C] |
-20…68 |
| Analogue end point [°C] |
2…90 |
| In steps of [°C] |
0.1 |
| Accuracy / deviations |
| Flow monitoring |
| Accuracy (in the measuring range) |
± (0,8 % MW + 0,2 % MEW) |
| Repeatability |
± 0,2 % MEW |
| Temperature monitoring |
| Accuracy [K] |
± 2,5 (Q > 5 % MEW) |
| Response times |
| Flow monitoring |
| Start-up delay [s] |
0…50 |
| Response time [s] |
< 0.25; (dAP = 0, T09) |
| Damping for the switching output dAP [s] |
0…5 |
| Temperature monitoring |
| Response time [s] |
15; (Q > 10 % MEW, T09) |
| Software / programming |
| Parameter setting options |
hysteresis / window; normally open / normally closed; switching logic; frequency output; current/pulse output; start-up delay; display can be deactivated; Display unit |
| Interfaces |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| SIO mode |
yes |
| Required master port type |
A |
| Process data analogue |
3 |
| Process data binary |
2 |
| Min. process cycle time [ms] |
6 |
| Supported DeviceIDs |
| Type of operation |
DeviceID |
| Default |
960 |
|
| Operating conditions |
| Ambient temperature [°C] |
-20…60 |
| Storage temperature [°C] |
-25…80 |
| Protection |
IP 65; IP 67 |
| Mechanical data |
| Weight [g] |
842 |
| Materials |
stainless steel (1.4408/316); stainless steel (1.4404 / 316L); PC; PBT+PC-GF30 |
| Materials (wetted parts) |
stainless steel (1.4404 / 316L); PEEK; carbon fibre PEEK; FKM |
| Process connection |
Rc 3/4 DN20 |
| Displays / operating elements |
| Display |
| |
colour display 1,44″, 128 x 128 pixels |
| |
2 x LED, yellow |
|
| Remarks |
| Remarks |
| MW = measured value |
| MEW = Final value of the measuring range |
|
| Pack quantity |
1 pcs. |
| Electrical connection |
| Connection |
Connector: 1 x M12; Contacts: gold-plated |