Cảm biến lưu lượng IFM SV4500 12 bar

Product characteristics
Number of inputs and outputs Number of digital outputs: 2
Measuring range
 
1…20 l/min 0.06…1.2 m³/h
Process connection threaded connection Rc 1/2 internal thread DN8
Application
Special feature Gold-plated contacts
Application for industrial applications
Media water
Medium temperature [°C] -10…90
Pressure rating [bar] 12
Pressure rating [Mpa] 1.2
Note on pressure rating
 
up to 40 °C
Electrical data
Operating voltage [V] 18…30 DC
Current consumption [mA] < 30
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] < 3
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2
Outputs
Total number of outputs 2
Output signal switching signal; frequency signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 100
Short-circuit protection yes
Overload protection yes
Measuring/setting range
Measuring range
 
1…20 l/min 0.06…1.2 m³/h
Display range
 
0…24 l/min 0…1.44 m³/h
Resolution
 
0.1 l/min 0.005 m³/h
Set point SP
 
1.2…20 l/min 0.07…1.2 m³/h
Reset point rP
 
1…19.8 l/min 0.06…1.19 m³/h
Frequency end point, FEP
 
4…20 l/min 0.24…1.2 m³/h
In steps of
 
0.1 l/min 0.005 m³/h
Frequency at the end point FRP [Hz] 100…1000
Measuring dynamics 1:20
Temperature monitoring
Measuring range [°C] -10…90
Display range [°C] -30…110
Resolution [°C] 0.5
Set point SP [°C] -9…90
Reset point rP [°C] -10…89
In steps of [°C] 0.5
Frequency start point, FSP [°C] -10…70
Frequency end point, FEP [°C] 10…90
Frequency at the end point FRP [Hz] 100…1000
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring range) ± 2 % MEW
Repeatability ± 0,5 % MEW
Temperature monitoring
Accuracy [K] ± 1
Response times
Flow monitoring
Response time [s] 1; (dAP = 0)
Damping for the switching output dAP [s] 0…5
Temperature monitoring
Dynamic response T05 / T09 [s] T09 = 6
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switching logic; frequency output; switch-on/switch-off delay; Damping; Display unit
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode yes
Required master port type A
Process data analogue 2
Process data binary 2
Min. process cycle time [ms] 3
Supported DeviceIDs
 
Type of operation DeviceID
Default 484
Operating conditions
Ambient temperature [°C] 0…60
Note on ambient temperature
 
medium temperature < 80 °C
medium temperature < 90 °C: 0…50 °C
Storage temperature [°C] -20…80
Protection IP 65; IP 67
Mechanical data
Weight [g] 442
Materials stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U
Materials (wetted parts) stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM
Tightening torque [Nm] 30
Process connection threaded connection Rc 1/2 internal thread DN8
Remarks
Remarks
 
MW = measured value
MEW = Final value of the measuring range
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; Contacts: gold-plated

Sản phẩm cùng loại

Gửi tin nhắn
Gọi cho chúng tôi
Chat qua facebook
Chat qua zalo
Văn phòng