Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 4 |
Probe length L [mm] |
100…1600 |
Process connection |
G 3/4 external thread |
Application |
Special feature |
Gold-plated contacts |
Installation |
Operation only in conjunction with rod and coaxial pipe. |
Media |
hydrous coolants; oils; oil-based media; water; media similar to water |
Dielectric constant of the medium |
≥ 2 |
Cannot be used for |
See the operating instructions, chapter “Function and features”. |
Medium temperature [°C] |
0…80 |
Tank pressure [bar] |
-0.5…4 |
Electrical data |
Operating voltage [V] |
18…30 DC |
Current consumption [mA] |
< 65 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
< 3 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 4 |
Outputs |
Total number of outputs |
4 |
Output signal |
switching signal |
Electrical design |
PNP |
Number of digital outputs |
4 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
200 |
Short-circuit protection |
yes |
Type of short-circuit protection |
thermal, pulsed |
Overload protection |
yes |
Measuring/setting range |
Probe length L [mm] |
100…1600 |
Active range A [mm] |
L-40 (L-60); (when set to oil and oil based media) |
Inactive range I1 / I2 [mm] |
30 / 10 (30); (when set to oil and oil based media) |
Setting range |
Set point SP [mm] |
≥ 15 (35) / ≤ L-30 |
Note on setpoint SP |
when set to oil and oil based media |
|
Reset point rP [mm] |
≥ 10 (30) / ≤ L-35 |
Note on reset point rP |
when set to oil and oil based media |
|
In steps of [mm] |
5 |
Hysteresis [mm] |
> 5 |
Overflow switch point OP [mm] |
70…L-30 |
Hysteresis, OP [mm] |
10 |
Accuracy / deviations |
Repeatability [mm] |
± 5 |
Switch point accuracy [mm] |
± (15 + 0,5 % ); (% of the final value of the measuring range: L – 30 mm) |
Operating conditions |
Ambient temperature [°C] |
0…60 |
Storage temperature [°C] |
-25…80 |
Protection |
IP 67 |
Mechanical data |
Weight [g] |
402 |
Materials |
stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); FKM; PBT-GF20; PC; PEI; TPV |
Materials (wetted parts) |
stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR-PPTA 20 |
Process connection |
G 3/4 external thread |
Displays / operating elements |
Display |
Display unit |
3 x LED, green |
switching status |
4 x LED, yellow |
level |
alphanumeric display, 4-digit |
parameter setting |
alphanumeric display, 4-digit |
|
Remarks |
Notes |
For 8-pole sockets the core colours are not standardised.; Please note the wiring of the sensor and the sockets (see data sheet). |
Pack quantity |
1 pcs. |
Electrical connection |
Connection |