Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
Factory setting |
hydrous media; probe length L = 400 mm |
Probe length L [mm] |
100…1600 |
Process connection |
G 3/4 external thread |
Application |
Special feature |
Gold-plated contacts |
Media |
Liquids |
Dielectric constant of the medium |
≥ 1,8; (for media with a dielectric constant of 1.8…5 (e.g. oils), a coaxial pipe is needed for operation) |
Recommended media |
water; hydrous media; oils; oil-based media |
Cannot be used for |
See the operating instructions, chapter “Function and features”. |
Medium temperature [°C] |
-25…80; (90 < 1 h) |
Tank pressure [bar] |
-1…16 |
Electrical data |
Operating voltage [V] |
18…30 DC |
Current consumption [mA] |
< 25 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
< 3 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs |
Total number of outputs |
2 |
Output signal |
analogue signal; IO-Link |
Electrical design |
PNP |
Number of digital outputs |
1 |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4…20, invertible |
Max. load [Ω] |
500 |
Analogue voltage output [V] |
0…10, invertible |
Min. load resistance [Ω] |
2000 |
Short-circuit protection |
yes |
Type of short-circuit protection |
thermal, pulsed |
Overload protection |
yes |
Measuring/setting range |
Factory setting |
hydrous media; probe length L = 400 mm |
Probe length L [mm] |
100…1600 |
Active range A [mm] |
L-40; (when set to oil and oil based media: L-60) |
Inactive range I1 / I2 [mm] |
30 / 10; (when set to oil and oil based media: 30 / 30) |
Sampling rate [Hz] |
4 |
Accuracy / deviations |
Repeatability [mm] |
± 5 |
Measuring error [mm] |
± 7 |
Offset error [mm] |
5 |
Resolution [mm] |
1 |
Zero signal (voltage) [V] |
0 |
Zero signal (current) [mA] |
4 |
Full signal (voltage) [V] |
10 |
Full signal (current) [mA] |
20 |
Temperature drift per 10 K |
± 0.2 % |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 CDV |
Profiles |
no profile |
SIO mode |
no |
Required master port type |
A |
Process data analogue |
1 |
Min. process cycle time [ms] |
2.3 |
Supported DeviceIDs |
Type of operation |
DeviceID |
Default |
685 |
|
Operating conditions |
Ambient temperature [°C] |
-25…60 |
Storage temperature [°C] |
-40…85 |
Protection |
IP 68; IP 69K; (7 days / 1 m water depth / 0.1 bar: IP 68) |
Mechanical data |
Weight [g] |
469 |
Materials |
stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PEI |
Materials (wetted parts) |
stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR reinforced fibre |
Process connection |
G 3/4 external thread |
Remarks |
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12; Contacts: gold-plated |