| Product characteristics |
| Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
| Measuring range |
|
| Process connection |
threaded connection G 1 external thread Aseptoflex Vario |
| Installation length EL [mm] |
87.5 |
| Application |
| Special feature |
Gold-plated contacts |
| Measuring element |
1 x Pt 1000 + 1 x NTC; (thermically coupled, with backup function (temperature measuring even if one element fails)) |
| Media |
liquids and gases |
| Pressure rating [bar] |
50 |
| Minimum installation depth [mm] |
25 |
| MAWP (for applications according to CRN) [bar] |
50 |
| Electrical data |
| Operating voltage [V] |
18…32 DC; (“supply class 2” to cULus) |
| Current consumption [mA] |
6; (24 V) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time [s] |
8 |
| Integrated watchdog |
yes |
| Inputs / outputs |
| Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
| Outputs |
| Total number of outputs |
2 |
| Output signal |
switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
1 |
| Output function |
normally open / normally closed / diagnostic signal; (parameterisable) |
| Max. voltage drop switching output DC [V] |
2 |
| Permanent current rating of switching output DC [mA] |
150; (200 (…60°C); 250 (…40 °C)) |
| Diagnostic output |
diagnostic output for drift and fault monitoring |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4…20 |
| Max. load [Ω] |
(Ub – 15 V) x 50 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Overload protection |
yes |
| Measuring/setting range |
| Measuring range |
|
| Note on measuring range |
|
| Factory setting |
0…150 °C / 32…302 °F |
| Drift warning |
|
| Drift alarm |
|
| In steps of |
|
| Resolution |
| Resolution of analogue output [K] |
0.05 |
| Accuracy / deviations |
| Precision analogue output [K] |
± 0,2 (-10…130°C); ± 0,3 (130…140°C); ± 0,3 ± 0,1% MS (-25…-10/140…160°C); (probe completely inserted into the measured medium up to the sealing chamfer) |
| Temperature coefficient [% of the span / 10 K] |
< ± 0,01; (in case of deviation from the reference condition 25 ± 5 °C) |
| Response times |
| Dynamic response T05 / T09 [s] |
3 / 6 |
| Software / programming |
| Parameter setting options |
drift warning/drift alarm threshold; Fail-Safe; Display unit; scaling of the analogue output; redundancy switching; performance diagnostic output; switching logic; normally open / normally closed |
| Interfaces |
| Communication interface |
IO-Link |
| Transmission type |
COM1 (4,8 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 CDV |
| Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| SIO mode |
yes |
| Required master port type |
A |
| Process data analogue |
1 |
| Process data binary |
1 |
| Min. process cycle time [ms] |
18.8 |
| Supported DeviceIDs |
| Type of operation |
DeviceID |
| Default |
323 |
|
| Operating conditions |
| Ambient temperature [°C] |
-25…70 |
| Storage temperature [°C] |
-40…85 |
| Protection |
IP 68; IP 69K |
| Mechanical data |
| Weight [g] |
411.5 |
| Materials |
stainless steel (1.4435 / 316L); stainless steel (1.4404 / 316L); PEI; FKM |
| Materials (wetted parts) |
stainless steel (1.4435 / 316L); stainless steel (1.4404 / 316L) |
| Process connection |
threaded connection G 1 external thread Aseptoflex Vario |
| Surface characteristics Ra/Rz of the wetted parts |
Ra: < 0.6 |
| Installation length EL [mm] |
87.5 |
| Remarks |
| Remarks |
|
| Pack quantity |
1 pcs. |
| Electrical connection |
| Connection |
Connector: 1 x M12; Contacts: gold-plated |