| Model | FD-R200 | |||
| Supported pipe diameter | 6″ (150 A), ø152 to ø191 5.98″ to 7.52″8″ (200 A), ø191 to ø220 7.52″ to 8.66″ | |||
| Supported pipe materials | Metal / resin*1 | |||
| Supported fluids | Various liquids (i.e. water, oils, chemicals)*1 | |||
| Supported fluid temperature | – 20 to + 120°C – 4.0 to + 248 °F (no freezing on the pipe surface)*2 | |||
| Maximum rated flow | Rated flow velocity range: 5.0 m/sFlow rate range (Typical):6″ (150 A): 5500 L/min 1400 gal/min 330 m3 /h8″(200 A): 9500 L/min 2500 gal/min 570 m3 /h | |||
| Zero cut flow rate | Zero cut: 0.3 m/s (default)*3Flow rate (Typical): 570 L / min 150 gal / min 36 m3 / h | |||
| Display method | Dual row, 5-digit display with white, 14-segment LED; Large status indicator; Output indicators; Stability indicator; Unit indicator | |||
| Display update cycle | Approx. 3 Hz | |||
| Display resolution | 1 (L / min) | |||
| Response time | 0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s (variable) | |||
| Measurement accuracy | Between 20 and 100% of F.S. : ±2.0% of RD*4*5Between 6 and 20% of F.S. : ±0.4% of F.S. *4*5 | |||
| Protection circuit | Power supply reverse connection protection, Power supply surge protection, Short-circuit protection for each output, Surge protection for each output | |||
| Zero point error | ±0.5% of F.S.*4*6 | |||
| Hysteresis | Variable | |||
| Flow units | L / min, m3 / h, gal / min | |||
| Integrated flow unit display | 1 / 10 / 100 / 1000 / 10000 (L) | |||
| Pipe temperature measurement accuracy | ±3°C ±5.4°F (liquid temperature of – 20 to + 50°C, – 4 to + 122°F)±5°C ±9°F (liquid temperature of 50 to + 120°C, 122 to 248°F)(ambient operating temperature of 25°C 77°F)*4 | |||
| Wiring specifications | Power supply | DC power supply: M12 4-pin connector / AC power supply: M4 screw terminal block (selectable) | ||
| I/O | When using a DC power supply: M12 4-pin connector / when using an AC power supply: M3 screw terminal block | |||
| Input/Output (Selectable) | Output (ch.1/ch.2) | Control output / Integrated pulse output / Error output / Temperature alarm, NPN / PNP setting switchable,open collector output 30 VDC or less, max. 100 mA / ch., residual voltage: 2.5 V or less*7 | ||
| Analog output (ch.1/ch.2) | Flow rate analog output / Temperature analog output and 4 – 20 mA / 0 – 20 mA (selectable), load resistance: 500 Ω or less*7 | |||
| External input (ch.2) | Integrated flow reset input / Flow rate zero input / Origin adjustment input (selectable), short-circuit current: 1.5 mA or less, input time: 20 ms or more*7 | |||
| Rating | Power voltage | 20 to 30 VDC including 10% ripple (P-P), Class 2 / 100 to 240 VAC – 15% or + 10% (50 / 60 Hz) | ||
| Current consumption | When using a DC power supply: 200 mA or less (load current excluded), 400 mA or less (load current included) When using an AC power supply: 15 VA or less | |||
| Environmental resistance | Enclosure rating | IP65 / 67 (IEC60259), IP69K (ISO20653), Enclosure Type 4X (NEMA250) | ||
| Ambient temperature | – 20 to + 60°C – 4.0 to 140 °F (no freezing)*2 | |||
| Relative humidity | 5 to 90%RH (no condensation) | |||
| Vibration resistance | 10 to 55 Hz, compound amplitude 1.5 mm 0.06″, XYZ axes 2 hours for each axis | |||
| Shock resistance | 100 m/s2 , 16 ms pulse, XYZ axes, 1000 times for each axis | |||
| Dimensions | Main unit size: 218.5 mm × 66.9 mm × 70.7 mm 8.60″ × 2.63″ × 2.78″ | |||
| Material | Main unit | Body: aluminum die-casting + coating / PPS, display: reinforced glass, connectors: SUS304-equivalent | ||
| Unit rear | Rubber | |||
| Upper/lower bracket | SUS304 | |||